← New York

Tap water quality report

Holland, NY

EPA monitoring detected 32 contaminants across the 3 water suppliers serving Holland. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

3
water suppliers
1,860
people served
32
contaminants found

What was found in Holland's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Barium
1654 µg/L 83%
of the EPA limit 2000 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
3/3 SYR4
Fluoride
120 µg/L 3%
of the EPA limit 4000 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 200 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
3/3 SYR4
Monobromoacetic Acid
90.2 µg/L
No EPA limit set
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Nitrate
60 µg/L 0.6%
of the EPA limit 10000 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 74 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
3/3 SYR4
Total Haloacetic Acids (HAA5)
0.7200 µg/L 1.2%
of the EPA limit 60 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 16.995 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
3/3 SYR4
TTHM
5.607 µg/L 7%
of the EPA limit 80 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 12.715 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
3/3 SYR4
Trichloroacetic Acid
0.7200 µg/L
No EPA limit set
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 9.8 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Bromoform
4.464 µg/L
No EPA limit set
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 7.33 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Bromodichloromethane
6.6 µg/L
No EPA limit set
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Cyanide
5 µg/L 2.5%
of the EPA limit 200 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
Dibromoacetic Acid
4.77 µg/L
No EPA limit set
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Combined Radium (-226 And -228)
3.866 pCi/L 77%
of the EPA limit 5 pCi/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 4.114 pCi/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
3/3 SYR4
Combined Uranium
3.0777 µg/L 10%
of the EPA limit 30 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 4 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2013
3/3 SYR4
Selenium
4 µg/L 8%
of the EPA limit 50 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
2/3 SYR4
Dichloroacetic Acid
3.44 µg/L
No EPA limit set
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Dibromochloromethane
1.258 µg/L
No EPA limit set
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 2.68 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Gross Beta Particle Activity
2.5 pCi/L
No EPA limit set
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2013
2/3 SYR4
Antimony, Total
0.3000 µg/L 5%
of the EPA limit 6 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
Highest in the city: 2.1 µg/L — HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
2/3 SYR4
Chloroform
1.86 µg/L
No EPA limit set
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Gross Alpha, Excl. Radon And U
1.8375 pCi/L 12%
of the EPA limit 15 pCi/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
3/3 SYR4
Benzene
1.105 µg/L 22%
of the EPA limit 5 µg/L
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Chromium
1.1 µg/L 1.1%
of the EPA limit 100 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
1,2-Dichloropropane
0.6190 µg/L 12%
of the EPA limit 5 µg/L
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Toluene
0.5250 µg/L 0.1%
of the EPA limit 1000 µg/L
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Monochloroacetic Acid
0.5000 µg/L
No EPA limit set
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Arsenic
0.4000 µg/L 4%
of the EPA limit 10 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
1,2-Dichloroethane
0.2450 µg/L 4.9%
of the EPA limit 5 µg/L
Highest in the city: HUNTERS CREEK MOBILE HOME PARK · 150 people · 2019
1/3 SYR4
Beryllium, Total
0.2000 µg/L 5%
of the EPA limit 4 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
Mercury
0.0800 µg/L 4%
of the EPA limit 2 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
Cadmium
0.0700 µg/L 1.4%
of the EPA limit 5 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
Thallium, Total
0.0400 µg/L 2%
of the EPA limit 2 µg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2019
1/3 SYR4
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
Main supplier: HOLLAND WATER DISTRICT · 1,680 people · 2025
Highest in the city: 0.0032 mg/L — HOLLAND HILLS APARTMENTS · 30 people · 2025
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Holland

Frequently asked questions about Holland tap water

Is Holland tap water safe to drink?

EPA testing detected 32 contaminants in the water serving Holland. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Holland?

3 public water suppliers report drinking-water monitoring for Holland, New York to the EPA. Each is listed above with its population served.

What contaminants are in Holland's water?

The contaminants EPA monitoring detected in Holland include Barium, Fluoride, Monobromoacetic Acid, Nitrate, Total Haloacetic Acids (HAA5). The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.