← New Jersey

Tap water quality report

Cape May Point boro-0503, NJ

EPA monitoring detected 13 contaminants across the 1 water supplier serving Cape May Point boro-0503. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

1
water supplier
4,000
people served
13
contaminants found

What was found in Cape May Point boro-0503's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Copper
461.3 µg/L 35%
of the EPA limit 1300 µg/L
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
TTHM
32.45 µg/L 41%
of the EPA limit 80 µg/L
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Bromoform
17.415 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Dibromochloromethane
11.45 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Bromodichloromethane
5.97 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Lead
5.31 µg/L 35%
of the EPA limit 15 µg/L
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
4.798 µg/L 8%
of the EPA limit 60 µg/L
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Dibromoacetic Acid
3.8845 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Chloroform
2.745 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Dichloroacetic Acid
0.6370 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Monobromoacetic Acid
0.5595 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Trichloroacetic Acid
0.5285 µg/L
No EPA limit set
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2019
1/1 SYR4
Lead
0.0044 mg/L 29%
of the EPA limit 0.0150 mg/L
Main supplier: CAPE MAY POINT BORO WATE · 4,000 people · 2025
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Cape May Point boro-0503

SupplierPopulation served
CAPE MAY POINT BORO WATE 4,000

Frequently asked questions about Cape May Point boro-0503 tap water

Is Cape May Point boro-0503 tap water safe to drink?

EPA testing detected 13 contaminants in the water serving Cape May Point boro-0503. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Cape May Point boro-0503?

1 public water supplier report drinking-water monitoring for Cape May Point boro-0503, New Jersey to the EPA. Each is listed above with its population served.

What contaminants are in Cape May Point boro-0503's water?

The contaminants EPA monitoring detected in Cape May Point boro-0503 include Copper, TTHM, Bromoform, Dibromochloromethane, Bromodichloromethane. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.