← Connecticut

Tap water quality report

Lisbon, CT

EPA monitoring detected 31 contaminants across the 6 water suppliers serving Lisbon. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier for each below, with its EPA source and period.

6
water suppliers
43,416
people served
31
contaminants found

What was found in Lisbon's water

The level at the city's main supplier, the highest level anywhere in the city, the EPA limit for each, and where every figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2470 µg/L 25%
of the EPA limit 10000 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 4500 µg/L — ROUND HILL LLC - WELL# 1&2 · 72 people · 2019
6/6 SYR4
Nitrate-Nitrite
2625 µg/L 26%
of the EPA limit 10000 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 4460 µg/L — ROUND HILL LLC - WELL# 1&2 · 72 people · 2019
6/6 SYR4
Fluoride
992 µg/L 25%
of the EPA limit 4000 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
1/6 SYR4
Nitrite
860 µg/L 86%
of the EPA limit 1000 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
1/6 SYR4
Copper
107.5 µg/L 8.3%
of the EPA limit 1300 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 341.395 µg/L — JEWETT CITY WATER COMPANY · 6,840 people · 2019
6/6 SYR4
TTHM
115.47 µg/L 144%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
3/6 SYR4
Total Haloacetic Acids (HAA5)
66.4 µg/L 111%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 75.24 µg/L — JEWETT CITY WATER COMPANY · 6,840 people · 2019
3/6 SYR4
Chloroform
50.5 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 70.12 µg/L — JEWETT CITY WATER COMPANY · 6,840 people · 2019
3/6 SYR4
Trichloroacetic Acid
40.35 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2019
2/6 SYR4
Dichloroacetic Acid
32.9736 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2019
2/6 SYR4
Barium
11 µg/L 0.5%
of the EPA limit 2000 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 18.8351 µg/L — TUNNEL HILL MOBILE HOME PARK · 40 people · 2019
6/6 SYR4
Lead
17.6 µg/L 117%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
6/6 SYR4
Bromodichloromethane
7.65 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
3/6 SYR4
Gross Alpha, Excl. Radon And U
4.3885 pCi/L 29%
of the EPA limit 15 pCi/L
Highest in the city: ROUND HILL LLC - WELL# 1&2 · 72 people · 2019
4/6 SYR4
Gross Beta Particle Activity
3.74 pCi/L
No EPA limit set
Highest in the city: TUNNEL HILL MOBILE HOME PARK · 40 people · 2019
1/6 SYR4
Dibromochloromethane
0.8725 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
Highest in the city: 3.72 µg/L — JEWETT CITY WATER CO-HILL-N-DALE · 146 people · 2019
3/6 SYR4
Monochloroacetic Acid
3.33 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2019
2/6 SYR4
Selenium
2.6 µg/L 5.2%
of the EPA limit 50 µg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2019
1/6 SYR4
Combined Radium (-226 And -228)
1.09 pCi/L 22%
of the EPA limit 5 pCi/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2017
Highest in the city: 2 pCi/L — JEWETT CITY WATER CO-HILL-N-DALE · 146 people · 2018
5/6 SYR4
Dibromoacetic Acid
1.62 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER CO-HILL-N-DALE · 146 people · 2019
2/6 SYR4
Monobromoacetic Acid
1.55 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2019
1/6 SYR4
Chromium
1 µg/L 1%
of the EPA limit 100 µg/L
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2019
1/6 SYR4
Bromoform
0.6170 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER CO-HILL-N-DALE · 146 people · 2019
2/6 SYR4
2,4-D
0.1650 µg/L 0.2%
of the EPA limit 70 µg/L
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2019
1/6 SYR4
PFOS
0.0162 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2024
1/6 UCMR-5
PFHXS
0.0125 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2024
1/6 UCMR-5
Pfba
0.0121 µg/L
No EPA limit set
Highest in the city: JEWETT CITY WATER COMPANY · 6,840 people · 2023
1/6 UCMR-5
PFOA
0.0067 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2024
1/6 UCMR-5
PFBS
0.0060 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2024
1/6 UCMR-5
Pfpea
0.0039 µg/L
No EPA limit set
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2024
1/6 UCMR-5
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
Main supplier: NORWICH PUBLIC UTILITIES · 36,163 people · 2025
Highest in the city: 0.0028 mg/L — ROUND HILL LLC - WELL# 1&2 · 72 people · 2024
6/6 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately. These are the utilities' own EPA-reported results, not a city-wide average. A detection means the lab measured the substance — it isn't the same as exceeding a legal limit. Hover a source tag to see the EPA program and years behind each figure.

Water suppliers serving Lisbon

Frequently asked questions about Lisbon tap water

Is Lisbon tap water safe to drink?

EPA testing detected 31 contaminants in the water serving Lisbon. A detection isn't the same as a violation — most detected levels are within federal limits. Check the level and source for each contaminant above, and your utility's annual Consumer Confidence Report for the official compliance status.

How many water suppliers serve Lisbon?

6 public water suppliers report drinking-water monitoring for Lisbon, Connecticut to the EPA. Each is listed above with its population served.

What contaminants are in Lisbon's water?

The contaminants EPA monitoring detected in Lisbon include Nitrate, Nitrate-Nitrite, Fluoride, Nitrite, Copper. The full list, with the level at the main supplier and the data source, is in the table above.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.