← Auburn, WA

Tap water quality report

ZIP 98001 — Auburn, WA

EPA monitoring across the 3 water suppliers serving ZIP 98001 in Auburn, WA detected 27 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

3
water suppliers
264,389
people served
27
contaminants found

What was found in ZIP 98001

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2515.5 µg/L 25%
of the EPA limit 10000 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
Highest in the ZIP: 3500 µg/L — Auburn City of · 107,655 people · 2019
3/3 SYR4
Nitrate-Nitrite
2600 µg/L 26%
of the EPA limit 10000 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
Highest in the ZIP: 3500 µg/L — Auburn City of · 107,655 people · 2018
3/3 SYR4
Fluoride
510 µg/L 13%
of the EPA limit 4000 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
1/3 SYR4
Copper
22 µg/L 1.7%
of the EPA limit 1300 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
Highest in the ZIP: 318 µg/L — Auburn City of · 107,655 people · 2018
2/3 SYR4
TTHM
42.66 µg/L 53%
of the EPA limit 80 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
3/3 SYR4
Chloroform
38.01 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
3/3 SYR4
Total Haloacetic Acids (HAA5)
34.72 µg/L 58%
of the EPA limit 60 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
3/3 SYR4
Trichloroacetic Acid
26 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
2/3 SYR4
Lead
3.04 µg/L 20%
of the EPA limit 15 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
Highest in the ZIP: 15.5 µg/L — Auburn City of · 107,655 people · 2018
2/3 SYR4
Dichloroacetic Acid
13.5 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
3/3 SYR4
Arsenic
7 µg/L 70%
of the EPA limit 10 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
2/3 SYR4
Bromodichloromethane
5.72 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
3/3 SYR4
Dibromochloromethane
3.93 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
Highest in the ZIP: 5.115 µg/L — Auburn City of · 107,655 people · 2019
3/3 SYR4
Selenium
2.3 µg/L 4.6%
of the EPA limit 50 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
1/3 SYR4
Dibromoacetic Acid
2.29 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
2/3 SYR4
Monochloroacetic Acid
2.1 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
1/3 SYR4
Bromoform
1.87 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
2/3 SYR4
Beryllium, Total
1.4 µg/L 35%
of the EPA limit 4 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
1/3 SYR4
Cadmium
1.4 µg/L 28%
of the EPA limit 5 µg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2019
2/3 SYR4
Monobromoacetic Acid
1.3 µg/L
No EPA limit set
Highest in the ZIP: Auburn City of · 107,655 people · 2019
1/3 SYR4
Pfpea
0.0137 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
1/3 UCMR-5
Pfhxa
0.0076 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
1/3 UCMR-5
PFHXS
0.0058 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
1/3 UCMR-5
PFBS
0.0040 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
Highest in the ZIP: 0.0041 µg/L — Auburn City of · 107,655 people · 2025
2/3 UCMR-5
PFOS
0.0041 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
1/3 UCMR-5
Pfhpa
0.0036 µg/L
No EPA limit set
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
1/3 UCMR-5
Lead
0.0033 mg/L 22%
of the EPA limit 0.0150 mg/L
Main supplier: LAKEHAVEN WATER AND SEWER DISTRICT · 148,809 people · 2025
3/3 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 98001

SupplierStatePopulation served
LAKEHAVEN WATER AND SEWER DISTRICT WA 148,809
Auburn City of WA 107,655
PACIFIC CITY OF WA 7,925

Frequently asked questions about ZIP 98001 tap water

Is the tap water in ZIP 98001 safe to drink?

EPA testing detected 27 contaminants across the water suppliers serving ZIP 98001. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 98001?

3 public water suppliers report EPA drinking-water monitoring for ZIP 98001. Each is listed above with its population served.

What contaminants are in ZIP 98001's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Fluoride, Copper, TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.