← Idaho Falls, ID

Tap water quality report

ZIP 83406 — Idaho Falls, ID

EPA monitoring across the 2 water suppliers serving ZIP 83406 in Idaho Falls, ID detected 22 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

2
water suppliers
39,988
people served
22
contaminants found

What was found in ZIP 83406

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate
2590 µg/L 26%
of the EPA limit 10000 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 3004 µg/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Nitrate-Nitrite
2317.5 µg/L 23%
of the EPA limit 10000 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 2972.5 µg/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Dibromochloromethane
684.226 µg/L
No EPA limit set
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Fluoride
370 µg/L 9.3%
of the EPA limit 4000 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
2/2 SYR4
Barium
126.05 µg/L 6.3%
of the EPA limit 2000 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 146.35 µg/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Lithium
44.6 µg/L
No EPA limit set
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2024
Highest in the ZIP: 47.1 µg/L — AMMON CITY OF · 17,338 people · 2024
2/2 UCMR-5
Gross Alpha, Excl. Radon And U
7.178 pCi/L 48%
of the EPA limit 15 pCi/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
2/2 SYR4
TTHM
7.109 µg/L 8.9%
of the EPA limit 80 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Combined Radium (-226 And -228)
0.5143 pCi/L 10%
of the EPA limit 5 pCi/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 3.955 pCi/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Combined Uranium
1.75 µg/L 5.8%
of the EPA limit 30 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 3.25 µg/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Copper
3 µg/L 0.2%
of the EPA limit 1300 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2017
1/2 SYR4
Chromium
3 µg/L 3%
of the EPA limit 100 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
2/2 SYR4
Bromoform
2.939 µg/L
No EPA limit set
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Di(2-ethylhexyl) Phthalate
0.9700 µg/L 16%
of the EPA limit 6 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 2.166 µg/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Arsenic
1.95 µg/L 20%
of the EPA limit 10 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
Highest in the ZIP: 2 µg/L — AMMON CITY OF · 17,338 people · 2019
2/2 SYR4
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
2/2 SYR4
Toluene
1.74 µg/L 0.2%
of the EPA limit 1000 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Dibromoacetic Acid
1.22 µg/L
No EPA limit set
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Total Haloacetic Acids (HAA5)
1.22 µg/L 2%
of the EPA limit 60 µg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Bromodichloromethane
1.08 µg/L
No EPA limit set
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2019
1/2 SYR4
Dichloromethane
1.06 µg/L 21%
of the EPA limit 5 µg/L
Highest in the ZIP: AMMON CITY OF · 17,338 people · 2019
1/2 SYR4
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
Main supplier: FALLS WATER COMPANY INC · 22,650 people · 2023
2/2 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 83406

SupplierStatePopulation served
FALLS WATER COMPANY INC ID 22,650
AMMON CITY OF ID 17,338

Frequently asked questions about ZIP 83406 tap water

Is the tap water in ZIP 83406 safe to drink?

EPA testing detected 22 contaminants across the water suppliers serving ZIP 83406. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 83406?

2 public water suppliers report EPA drinking-water monitoring for ZIP 83406. Each is listed above with its population served.

What contaminants are in ZIP 83406's water?

EPA monitoring detected Nitrate, Nitrate-Nitrite, Dibromochloromethane, Fluoride, Barium, and others across this ZIP's suppliers. The full list with levels and sources is above.