What was found in ZIP 51301
The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.
| Contaminant | Level vs EPA limit | Suppliers | Source |
|---|---|---|---|
| Nitrate | 110 µg/L 1.1% of the EPA limit 10000 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019
Highest in the ZIP: 1250 µg/L — IOWA LAKES REGIONAL WATER · 6,755 people · 2019 | 2/2 | SYR4 |
| Fluoride | 640 µg/L 16% of the EPA limit 4000 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2012 | 2/2 | SYR4 |
| Copper | 235 µg/L 18% of the EPA limit 1300 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2017 | 2/2 | SYR4 |
| TTHM | 53 µg/L 66% of the EPA limit 80 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019 | 2/2 | SYR4 |
| Chloroform | 27 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019
Highest in the ZIP: 29.7 µg/L — IOWA LAKES REGIONAL WATER · 6,755 people · 2019 | 2/2 | SYR4 |
| Total Haloacetic Acids (HAA5) | 11.2 µg/L 19% of the EPA limit 60 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019
Highest in the ZIP: 14.8325 µg/L — IOWA LAKES REGIONAL WATER · 6,755 people · 2019 | 2/2 | SYR4 |
| Bromodichloromethane | 14 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019 | 2/2 | SYR4 |
| Lithium | 11 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2023 | 1/2 | UCMR-5 |
| Dibromochloromethane | 9.62 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019 | 2/2 | SYR4 |
| Dichloroacetic Acid | 6 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019
Highest in the ZIP: 8.2 µg/L — IOWA LAKES REGIONAL WATER · 6,755 people · 2019 | 2/2 | SYR4 |
| Lead | 7.8 µg/L 52% of the EPA limit 15 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2017 | 2/2 | SYR4 |
| Trichloroacetic Acid | 3.3 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019
Highest in the ZIP: 4.395 µg/L — IOWA LAKES REGIONAL WATER · 6,755 people · 2019 | 2/2 | SYR4 |
| Dibromoacetic Acid | 3 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019 | 2/2 | SYR4 |
| Bromoform | 2.66 µg/L No EPA limit set Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2019 | 2/2 | SYR4 |
| Xylenes, Total | 2.28 µg/L 0% of the EPA limit 10000 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2018 | 1/2 | SYR4 |
| Toluene | 0.7800 µg/L 0.1% of the EPA limit 1000 µg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2018 | 1/2 | SYR4 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L Main supplier: SPENCER MUNICIPAL WATER UTILITY · 11,325 people · 2023
Highest in the ZIP: 0.00030 mg/L — IOWA LAKES REGIONAL WATER · 6,755 people · 2023 | 2/2 | LCR |
Water suppliers serving ZIP 51301
| Supplier | State | Population served |
|---|---|---|
| SPENCER MUNICIPAL WATER UTILITY | IA | 11,325 |
| IOWA LAKES REGIONAL WATER | IA | 6,755 |
Frequently asked questions about ZIP 51301 tap water
Is the tap water in ZIP 51301 safe to drink?
EPA testing detected 17 contaminants across the water suppliers serving ZIP 51301. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.
Which water suppliers serve ZIP 51301?
2 public water suppliers report EPA drinking-water monitoring for ZIP 51301. Each is listed above with its population served.
What contaminants are in ZIP 51301's water?
EPA monitoring detected Nitrate, Fluoride, Copper, TTHM, Chloroform, and others across this ZIP's suppliers. The full list with levels and sources is above.