← Camden city-0408, NJ

Tap water quality report

ZIP 08101 — Camden city-0408, NJ

EPA monitoring across the 1 water supplier serving ZIP 08101 in Camden city-0408, NJ detected 43 contaminants. A detection doesn't automatically mean the water is unsafe — see the level at the main supplier below, with the EPA limit for each.

1
water supplier
46,585
people served
43
contaminants found

What was found in ZIP 08101

The level at this ZIP's main supplier, the highest level anywhere in it, the EPA limit for each, and where the figure comes from.

ContaminantLevel vs EPA limitSuppliersSource
Nitrate-Nitrite
3176 µg/L 32%
of the EPA limit 10000 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Nitrate
3040 µg/L 30%
of the EPA limit 10000 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Fluoride
640 µg/L 16%
of the EPA limit 4000 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Copper
147.05 µg/L 11%
of the EPA limit 1300 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2018
1/1 SYR4
TTHM
61.9 µg/L 77%
of the EPA limit 80 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Barium
36.91 µg/L 1.8%
of the EPA limit 2000 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Cyanide
35 µg/L 18%
of the EPA limit 200 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Lithium
30.1 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
Dibromochloromethane
18 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Bromodichloromethane
17.85 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Chloroform
14.3 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Total Haloacetic Acids (HAA5)
13.855 µg/L 23%
of the EPA limit 60 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Lead
9.87 µg/L 66%
of the EPA limit 15 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2018
1/1 SYR4
Bromoform
9.615 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Dichloroacetic Acid
6.99 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Dibromoacetic Acid
6.32 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Selenium
5.06 µg/L 10%
of the EPA limit 50 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Chromium
4.655 µg/L 4.7%
of the EPA limit 100 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Trichloroacetic Acid
3.783 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Gross Alpha, Excl. Radon And U
3.455 pCi/L 23%
of the EPA limit 15 pCi/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
1,2-Dichloroethane
3.0925 µg/L 62%
of the EPA limit 5 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Combined Radium (-226 And -228)
1.788 pCi/L 36%
of the EPA limit 5 pCi/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Monochloroacetic Acid
1.251 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Arsenic
1.062 µg/L 11%
of the EPA limit 10 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Monobromoacetic Acid
1.0325 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
cis-1,2-Dichloroethylene
0.5050 µg/L 0.7%
of the EPA limit 70 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Trichloroethylene
0.4900 µg/L 9.8%
of the EPA limit 5 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Tetrachloroethylene
0.3600 µg/L 7.2%
of the EPA limit 5 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Combined Uranium
0.3204 µg/L 1.1%
of the EPA limit 30 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Chlorobenzene
0.2150 µg/L 0.2%
of the EPA limit 100 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
P-Dichlorobenzene
0.1780 µg/L 0.2%
of the EPA limit 75 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
Thallium, Total
0.1370 µg/L 6.9%
of the EPA limit 2 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Mercury
0.0887 µg/L 4.4%
of the EPA limit 2 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
Antimony, Total
0.0700 µg/L 1.2%
of the EPA limit 6 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2017
1/1 SYR4
1,1-Dichloroethylene
0.0400 µg/L 0.6%
of the EPA limit 7 µg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2019
1/1 SYR4
PFOS
0.0129 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
PFOA
0.0106 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
Pfba
0.0079 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
Pfpea
0.0075 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
Pfhxa
0.0064 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
PFNA
0.0062 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
Pfhpa
0.0044 µg/L
No EPA limit set
Main supplier: CITY OF CAMDEN · 46,585 people · 2024
1/1 UCMR-5
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
Main supplier: CITY OF CAMDEN · 46,585 people · 2026
1/1 LCR
Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of the system's samples — over 100% is worth reading, but is not by itself a violation. Formal violations are listed separately.

Water suppliers serving ZIP 08101

SupplierStatePopulation served
CITY OF CAMDEN NJ 46,585

Frequently asked questions about ZIP 08101 tap water

Is the tap water in ZIP 08101 safe to drink?

EPA testing detected 43 contaminants across the water suppliers serving ZIP 08101. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and your utility's annual Consumer Confidence Report for the official status.

Which water suppliers serve ZIP 08101?

1 public water supplier report EPA drinking-water monitoring for ZIP 08101. Each is listed above with its population served.

What contaminants are in ZIP 08101's water?

EPA monitoring detected Nitrate-Nitrite, Nitrate, Fluoride, Copper, TTHM, and others across this ZIP's suppliers. The full list with levels and sources is above.