← Wyoming

Tap water quality report

Freedom Hills Subdivision

EPA monitoring tested this supplier for 78 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
13
detected
400
people served
1
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Campbell

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
31
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2004-10-01 → 2004-10-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2004-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31
MR Monitoring Resolved 2002-01-01 → 2002-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate-Nitrite
50 µg/L 0.5%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Copper
134.5 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 148 µg/L
10/10 SYR4 2015–2018
Lead
0.0010 mg/L 6.7%
of the EPA limit 0.0150 mg/L
8/8 LCR 2024
Lead
9.6 µg/L 64%
of the EPA limit 15 µg/L
worst single sample: 11 µg/L
8/10 SYR4 2015–2018
Barium
119 µg/L 5.9%
of the EPA limit 2000 µg/L
worst single sample: 120 µg/L
3/3 SYR4 2012–2017
Dibromochloromethane
1.058 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
3/4 SYR4 2014–2017
Fluoride
2730 µg/L 68%
of the EPA limit 4000 µg/L
worst single sample: 2800 µg/L
3/3 SYR4 2012–2017
TTHM
2.76 µg/L 3.5%
of the EPA limit 80 µg/L
worst single sample: 2.8 µg/L
3/4 SYR4 2014–2017
Bromoform
1.081 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
2/4 SYR4 2014–2017
Bromodichloromethane
0.6800 µg/L
No EPA limit set
1/4 SYR4 2014–2017
Chloroform
0.2800 µg/L
No EPA limit set
1/4 SYR4 2014–2017
Combined Radium (-226 And -228)
0.7000 pCi/L 14%
of the EPA limit 5 pCi/L
1/2 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
2.3 pCi/L 15%
of the EPA limit 15 pCi/L
1/2 SYR4 2013–2019
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MELICK, CHEYENNE
Phone
307-299-3544
Email
[email protected]

Frequently asked questions about Freedom Hills Subdivision

Is Freedom Hills Subdivision tap water safe to drink?

EPA monitoring detected 13 contaminants in Freedom Hills Subdivision's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Freedom Hills Subdivision's water?

EPA monitoring detected Nitrate-Nitrite, Copper, Lead, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Freedom Hills Subdivision serve?

Freedom Hills Subdivision reports serving 400 people in Wyoming, per its EPA record.

Has Freedom Hills Subdivision had any water quality violations?

The EPA has 31 violations on file for Freedom Hills Subdivision, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.