← Wyoming

Tap water quality report

Glenrock, Town of

EPA monitoring tested this supplier for 81 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

81
contaminants tested
18
detected
2,466
people served
3
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Converse

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

3
health-based violations
9
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2022-09-25
MCL Health-based Archived 1994-06-01 → 1994-06-30
MCL Health-based Archived 1994-06-01 → 1994-06-30
Other Monitoring Unaddressed 2018-10-01
Other Monitoring Resolved 2008-07-01
MR Monitoring Resolved 2003-01-01 → 2003-12-31
MR Monitoring Resolved 2003-01-01 → 2003-12-31
MR Monitoring Archived 1976-07-01 → 1980-06-30
MR Monitoring Archived 1976-07-01 → 1980-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
318.25 µg/L 24%
of the EPA limit 1300 µg/L
worst single sample: 475 µg/L
20/20 SYR4 2014–2017
Lead
4.2 µg/L 28%
of the EPA limit 15 µg/L
worst single sample: 6 µg/L
13/20 SYR4 2014–2017
TTHM
5.26 µg/L 6.6%
of the EPA limit 80 µg/L
worst single sample: 5.3 µg/L
9/10 SYR4 2013–2019
Dibromochloromethane
1.93 µg/L
No EPA limit set
worst single sample: 2 µg/L
8/9 SYR4 2014–2019
Nitrate-Nitrite
600 µg/L 6%
of the EPA limit 10000 µg/L
8/8 SYR4 2012–2019
Lead
0.0020 mg/L 13%
of the EPA limit 0.0150 mg/L
7/7 LCR 2023
Bromodichloromethane
1.775 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
6/9 SYR4 2014–2019
Dibromoacetic Acid
0.7400 µg/L
No EPA limit set
worst single sample: 0.7700 µg/L
6/7 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
2.1 µg/L 3.5%
of the EPA limit 60 µg/L
6/8 SYR4 2013–2019
Bromoform
0.8240 µg/L
No EPA limit set
worst single sample: 0.8400 µg/L
5/9 SYR4 2014–2019
Chloroform
2.395 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
4/9 SYR4 2014–2019
Combined Radium (-226 And -228)
1.08 pCi/L 22%
of the EPA limit 5 pCi/L
worst single sample: 1.1 pCi/L
3/3 SYR4 2012–2018
Dichloroacetic Acid
1.46 µg/L
No EPA limit set
worst single sample: 1.5 µg/L
3/7 SYR4 2014–2019
Fluoride
190 µg/L 4.8%
of the EPA limit 4000 µg/L
worst single sample: 200 µg/L
3/3 SYR4 2012–2017
Gross Alpha, Excl. Radon And U
5.385 pCi/L 36%
of the EPA limit 15 pCi/L
worst single sample: 5.4 pCi/L
2/2 SYR4 2012–2018
Nitrate
600 µg/L 6%
of the EPA limit 10000 µg/L
2/2 SYR4 2012
Arsenic
3 µg/L 30%
of the EPA limit 10 µg/L
1/3 SYR4 2012–2017
Combined Uranium
6.3 µg/L 21%
of the EPA limit 30 µg/L
1/1 SYR4 2018
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FUNK, JOHN
Phone
307-259-0945
Email
[email protected]

Frequently asked questions about Glenrock, Town of

Is Glenrock, Town of tap water safe to drink?

EPA monitoring detected 18 contaminants in Glenrock, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Glenrock, Town of's water?

EPA monitoring detected Copper, Lead, TTHM, Dibromochloromethane, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Glenrock, Town of serve?

Glenrock, Town of reports serving 2,466 people in Wyoming, per its EPA record.

Has Glenrock, Town of had any water quality violations?

The EPA has 9 violations on file for Glenrock, Town of, of which 3 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.