← Wyoming

Tap water quality report

Worland Utilities Commission

EPA monitoring tested this supplier for 77 contaminants and detected 9. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
9
detected
4,787
people served
1
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Washakie

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

1
health-based violations
18
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1998-07-01 → 1998-07-31
MR Monitoring Resolved 2016-01-01 → 2016-01-31
MR Monitoring Resolved 2016-01-01 → 2016-01-31
MR Monitoring Resolved 2015-09-29
MR Monitoring Resolved 2014-12-01 → 2014-12-31
MR Monitoring Resolved 2003-01-01 → 2003-12-31
MR Monitoring Resolved 2003-01-01 → 2003-12-31
MR Monitoring Archived 1991-02-01 → 1991-02-28
MR Monitoring Archived 1983-08-01 → 1984-07-31
MR Monitoring Archived 1983-08-01 → 1984-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
210.3 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 583 µg/L
98/99 SYR4 2014–2019
Lead
9.75 µg/L 65%
of the EPA limit 15 µg/L
worst single sample: 132 µg/L
50/99 SYR4 2014–2019
Lead
0.0030 mg/L 20%
of the EPA limit 0.0150 mg/L
10/10 LCR 2025
TTHM
2.3 µg/L 2.9%
of the EPA limit 80 µg/L
worst single sample: 2.4 µg/L
3/8 SYR4 2014–2019
Nitrate-Nitrite
500 µg/L 5%
of the EPA limit 10000 µg/L
2/2 SYR4 2019
Total Haloacetic Acids (HAA5)
0.7675 µg/L 1.3%
of the EPA limit 60 µg/L
worst single sample: 0.7800 µg/L
2/7 SYR4 2014–2019
Arsenic
2 µg/L 20%
of the EPA limit 10 µg/L
1/1 SYR4 2019
Fluoride
200 µg/L 5%
of the EPA limit 4000 µg/L
1/1 SYR4 2019
Selenium
2 µg/L 4%
of the EPA limit 50 µg/L
1/1 SYR4 2019
68 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MARTINEZ, JOE
Phone
307-347-8978
Email
[email protected]

Frequently asked questions about Worland Utilities Commission

Is Worland Utilities Commission tap water safe to drink?

EPA monitoring detected 9 contaminants in Worland Utilities Commission's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Worland Utilities Commission's water?

EPA monitoring detected Copper, Lead, Lead, TTHM, Nitrate-Nitrite, and others. The full list with the level and data source for each is above.

How many people does Worland Utilities Commission serve?

Worland Utilities Commission reports serving 4,787 people in Wyoming, per its EPA record.

Has Worland Utilities Commission had any water quality violations?

The EPA has 18 violations on file for Worland Utilities Commission, of which 1 is health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.