← Wyoming

Tap water quality report

Salt Creek Water District

EPA monitoring tested this supplier for 73 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

73
contaminants tested
10
detected
600
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Weston

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
15
violations on file
1
still open
ViolationTypeStatusPeriod
MR Monitoring Unaddressed 2023-12-30
MR Monitoring Resolved 2023-10-01
MR Monitoring Resolved 2021-04-01
MR Monitoring Resolved 2021-04-01
MR Monitoring Resolved 2012-01-01
Other Monitoring Resolved 2006-10-01
Other Monitoring Resolved 2006-10-01
MR Monitoring Resolved 2004-01-01 → 2007-12-31
MR Monitoring Resolved 2004-01-01 → 2007-12-31
MR Monitoring Resolved 2004-01-01 → 2007-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
208.4 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 375 µg/L
35/35 SYR4 2014–2018
Nitrate-Nitrite
230 µg/L 2.3%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
11/11 LCR 2025
Lead
11.5 µg/L 77%
of the EPA limit 15 µg/L
worst single sample: 16 µg/L
10/35 SYR4 2014–2018
Arsenic
6.8 µg/L 68%
of the EPA limit 10 µg/L
worst single sample: 7 µg/L
3/3 SYR4 2013–2019
Barium
80 µg/L 4%
of the EPA limit 2000 µg/L
3/3 SYR4 2013–2019
Fluoride
700 µg/L 18%
of the EPA limit 4000 µg/L
3/3 SYR4 2013–2019
Selenium
4.9 µg/L 9.8%
of the EPA limit 50 µg/L
worst single sample: 5 µg/L
3/3 SYR4 2013–2019
Combined Radium (-226 And -228)
2 pCi/L 40%
of the EPA limit 5 pCi/L
1/1 SYR4 2016
Gross Alpha, Excl. Radon And U
6.5 pCi/L 43%
of the EPA limit 15 pCi/L
1/1 SYR4 2016
63 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebDiquatEthylene DibromideEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSimazineStyreneTTHMTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RICH, ZANNIE
Phone
307-746-3331
Email
[email protected]

Frequently asked questions about Salt Creek Water District

Is Salt Creek Water District tap water safe to drink?

EPA monitoring detected 10 contaminants in Salt Creek Water District's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Salt Creek Water District's water?

EPA monitoring detected Copper, Nitrate-Nitrite, Lead, Lead, Arsenic, and others. The full list with the level and data source for each is above.

How many people does Salt Creek Water District serve?

Salt Creek Water District reports serving 600 people in Wyoming, per its EPA record.

Has Salt Creek Water District had any water quality violations?

The EPA has 15 violations on file for Salt Creek Water District, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.