Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2003-09-01 → 2003-09-30 |
| MCL | Health-based | Resolved | 2003-09-01 → 2003-09-30 |
| Other | Monitoring | Resolved | 2017-10-05 |
| MON | Monitoring | Resolved | 2017-09-01 → 2017-09-30 |
| MR | Monitoring | Resolved | 2016-01-01 → 2016-12-31 |
| MR | Monitoring | Resolved | 2012-12-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-12-01 → 2012-12-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-01-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-01-31 |
| MR | Monitoring | Resolved | 2012-01-01 → 2012-01-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2024 |
| Copper | 151 µg/L 12% of the EPA limit 1300 µg/L
worst single sample: 160 µg/L | 10/10 | SYR4 | 2015–2018 |
| Nitrate-Nitrite | 2012 µg/L 20% of the EPA limit 10000 µg/L
worst single sample: 2090 µg/L | 7/8 | SYR4 | 2013–2019 |
| Fluoride | 381 µg/L 9.5% of the EPA limit 4000 µg/L
worst single sample: 390 µg/L | 3/3 | SYR4 | 2013–2017 |
| Arsenic | 1.285 µg/L 13% of the EPA limit 10 µg/L
worst single sample: 1.3 µg/L | 2/3 | SYR4 | 2013–2017 |
| Combined Uranium | 12 µg/L 40% of the EPA limit 30 µg/L | 2/2 | SYR4 | 2014 |
| Lead | 11.55 µg/L 77% of the EPA limit 15 µg/L
worst single sample: 12 µg/L | 2/10 | SYR4 | 2015–2018 |
| Nitrate | 1100 µg/L 11% of the EPA limit 10000 µg/L | 2/4 | SYR4 | 2012–2013 |
| Selenium | 1.965 µg/L 3.9% of the EPA limit 50 µg/L
worst single sample: 2 µg/L | 2/3 | SYR4 | 2013–2017 |
| Barium | 110 µg/L 5.5% of the EPA limit 2000 µg/L | 1/3 | SYR4 | 2013–2017 |
| Combined Radium (-226 And -228) | 0.2000 pCi/L 4% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2014 |
| Gross Alpha, Excl. Radon And U | 2 pCi/L 13% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2014 |
| Thallium, Total | 1.1 µg/L 55% of the EPA limit 2 µg/L | 1/3 | SYR4 | 2013–2017 |
63 contaminants tested, none detected
Utility contact
Frequently asked questions about Farson Mobile Home Court
Is Farson Mobile Home Court tap water safe to drink?
EPA monitoring detected 13 contaminants in Farson Mobile Home Court's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Farson Mobile Home Court's water?
EPA monitoring detected Lead, Copper, Nitrate-Nitrite, Fluoride, Arsenic, and others. The full list with the level and data source for each is above.
How many people does Farson Mobile Home Court serve?
Farson Mobile Home Court reports serving 20 people in Wyoming, per its EPA record.
Has Farson Mobile Home Court had any water quality violations?
The EPA has 118 violations on file for Farson Mobile Home Court, of which 2 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.