← Wyoming

Tap water quality report

Sinclair, Town of

EPA monitoring tested this supplier for 14 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
13
detected
433
people served
12
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Carbon

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

12
health-based violations
25
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2001-02-01 → 2001-02-28
TT Health-based Resolved 2001-02-01 → 2001-02-28
TT Health-based Resolved 1998-07-01 → 1998-07-31
TT Health-based Resolved 1998-06-01 → 1998-06-30
TT Health-based Resolved 1998-05-01 → 1998-05-31
TT Health-based Resolved 1997-07-01 → 1997-07-31
TT Health-based Resolved 1997-06-01 → 1997-06-30
TT Health-based Resolved 1997-05-01 → 1997-05-31
TT Health-based Resolved 1997-04-01 → 1997-04-30
TT Health-based Resolved 1997-03-01 → 1997-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
208 µg/L 16%
of the EPA limit 1300 µg/L
worst single sample: 250 µg/L
15/15 SYR4 2015–2019
Lead
5.55 µg/L 37%
of the EPA limit 15 µg/L
worst single sample: 6 µg/L
10/15 SYR4 2015–2019
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
9/9 LCR 2025
Bromodichloromethane
9.424 µg/L
No EPA limit set
worst single sample: 10 µg/L
7/7 SYR4 2014–2019
Chloroform
17.21 µg/L
No EPA limit set
worst single sample: 17.3 µg/L
7/7 SYR4 2014–2019
Dibromoacetic Acid
1.54 µg/L
No EPA limit set
worst single sample: 1.6 µg/L
7/7 SYR4 2014–2019
Dibromochloromethane
5.2 µg/L
No EPA limit set
7/7 SYR4 2014–2019
Dichloroacetic Acid
7.69 µg/L
No EPA limit set
worst single sample: 8.2 µg/L
7/7 SYR4 2014–2019
TTHM
32.16 µg/L 40%
of the EPA limit 80 µg/L
worst single sample: 33 µg/L
7/7 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
12.1 µg/L 20%
of the EPA limit 60 µg/L
worst single sample: 13 µg/L
7/7 SYR4 2014–2019
Trichloroacetic Acid
3.15 µg/L
No EPA limit set
worst single sample: 3.3 µg/L
6/7 SYR4 2014–2019
Bromoform
1.6 µg/L
No EPA limit set
worst single sample: 1.7 µg/L
5/7 SYR4 2014–2019
Monobromoacetic Acid
0.5700 µg/L
No EPA limit set
1/7 SYR4 2014–2019
1 contaminants tested, none detected
Monochloroacetic Acid

Utility contact

Contact
SLATER, BECKY
Phone
307-324-3058
Email
[email protected]

Frequently asked questions about Sinclair, Town of

Is Sinclair, Town of tap water safe to drink?

EPA monitoring detected 13 contaminants in Sinclair, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Sinclair, Town of's water?

EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does Sinclair, Town of serve?

Sinclair, Town of reports serving 433 people in Wyoming, per its EPA record.

Has Sinclair, Town of had any water quality violations?

The EPA has 25 violations on file for Sinclair, Town of, of which 12 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.