← West Virginia

Tap water quality report

Union Williams P S D

EPA monitoring tested this supplier for 75 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
20
detected
7,883
people served
16
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Wood

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

16
health-based violations
89
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2020-08-22
TT Health-based Resolved 2020-08-22
TT Health-based Resolved 2020-08-22
TT Health-based Resolved 2020-08-22
TT Health-based Resolved 2020-01-14
TT Health-based Resolved 2020-01-14
TT Health-based Resolved 2020-01-14
TT Health-based Resolved 2020-01-14
TT Health-based Resolved 2012-09-01 → 2012-09-30
TT Health-based Resolved 2012-09-01 → 2012-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
1237 µg/L 95%
of the EPA limit 1300 µg/L
worst single sample: 1860 µg/L
207/207 SYR4 2013–2019
Lead
2.9 µg/L 19%
of the EPA limit 15 µg/L
worst single sample: 13.2 µg/L
186/207 SYR4 2013–2019
Lead
0.00065 mg/L 4.3%
of the EPA limit 0.0150 mg/L
24/24 LCR 2026
Nitrate
1980 µg/L 20%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Bromoform
2.873 µg/L
No EPA limit set
worst single sample: 3.26 µg/L
10/10 SYR4 2012–2019
Dibromochloromethane
6.1415 µg/L
No EPA limit set
worst single sample: 6.2 µg/L
10/10 SYR4 2012–2019
TTHM
16.96 µg/L 21%
of the EPA limit 80 µg/L
worst single sample: 17.5 µg/L
10/10 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
32.58 µg/L 54%
of the EPA limit 60 µg/L
worst single sample: 47.7 µg/L
10/10 SYR4 2012–2019
Dibromoacetic Acid
2.986 µg/L
No EPA limit set
worst single sample: 3.29 µg/L
9/10 SYR4 2012–2019
Bromodichloromethane
5.823 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
8/10 SYR4 2012–2019
Chloroform
2.96 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
8/10 SYR4 2012–2019
Dichloroacetic Acid
3.72 µg/L
No EPA limit set
worst single sample: 4.18 µg/L
6/10 SYR4 2012–2019
Monobromoacetic Acid
10.144 µg/L
No EPA limit set
worst single sample: 10.7 µg/L
3/10 SYR4 2012–2019
Monochloroacetic Acid
3.181 µg/L
No EPA limit set
worst single sample: 3.29 µg/L
3/10 SYR4 2012–2019
Trichloroacetic Acid
38.167 µg/L
No EPA limit set
worst single sample: 42.2 µg/L
3/10 SYR4 2012–2019
Barium
36.975 µg/L 1.8%
of the EPA limit 2000 µg/L
worst single sample: 37 µg/L
2/2 SYR4 2016–2019
Fluoride
487.5 µg/L 12%
of the EPA limit 4000 µg/L
worst single sample: 490 µg/L
2/2 SYR4 2016–2019
Gross Alpha, Excl. Radon And U
1.26925 pCi/L 8.5%
of the EPA limit 15 pCi/L
worst single sample: 1.31 pCi/L
2/3 SYR4 2012–2017
Arsenic
1.1 µg/L 11%
of the EPA limit 10 µg/L
1/2 SYR4 2016–2019
Nitrite
280 µg/L 28%
of the EPA limit 1000 µg/L
1/2 SYR4 2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NULTER, STEPHEN L.
Phone
304-464-5121
Email
[email protected]

Frequently asked questions about Union Williams P S D

Is Union Williams P S D tap water safe to drink?

EPA monitoring detected 20 contaminants in Union Williams P S D's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Union Williams P S D's water?

EPA monitoring detected Copper, Lead, Lead, Nitrate, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Union Williams P S D serve?

Union Williams P S D reports serving 7,883 people in West Virginia, per its EPA record.

Has Union Williams P S D had any water quality violations?

The EPA has 89 violations on file for Union Williams P S D, of which 16 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.