Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2025-07-17 |
| TT | Health-based | Unaddressed | 2025-07-17 |
| TT | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| TT | Health-based | Archived | 2025-07-01 → 2025-09-30 |
| TT | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| TT | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| TT | Health-based | Resolved | 2025-01-01 → 2025-03-31 |
| TT | Health-based | Resolved | 2019-07-06 |
| TT | Health-based | Resolved | 2019-07-06 |
| TT | Health-based | Resolved | 2019-07-06 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| TTHM | 59.58 µg/L 74% of the EPA limit 80 µg/L
worst single sample: 102.8 µg/L | 25/25 | SYR4 | 2012–2019 |
| Bromodichloromethane | 10.77 µg/L No EPA limit set
worst single sample: 11.1 µg/L | 24/25 | SYR4 | 2012–2019 |
| Chloroform | 54.385 µg/L No EPA limit set
worst single sample: 94.9 µg/L | 24/25 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 26.085 µg/L No EPA limit set
worst single sample: 62.2 µg/L | 24/25 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 72.665 µg/L 121% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 121.1 µg/L | 24/25 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 48.55 µg/L No EPA limit set
worst single sample: 58.9 µg/L | 23/25 | SYR4 | 2012–2019 |
| Copper | 81 µg/L 6.2% of the EPA limit 1300 µg/L
worst single sample: 118 µg/L | 21/30 | SYR4 | 2013–2019 |
| Dibromochloromethane | 3.77 µg/L No EPA limit set
worst single sample: 5.1 µg/L | 15/25 | SYR4 | 2012–2019 |
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 15/15 | LCR | 2025 |
| Nitrate | 990 µg/L 9.9% of the EPA limit 10000 µg/L | 10/24 | SYR4 | 2013–2019 |
| Barium | 63.4 µg/L 3.2% of the EPA limit 2000 µg/L
worst single sample: 67 µg/L | 7/7 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 1.375 µg/L No EPA limit set
worst single sample: 1.4 µg/L | 6/25 | SYR4 | 2012–2019 |
| Fluoride | 727 µg/L 18% of the EPA limit 4000 µg/L
worst single sample: 750 µg/L | 3/7 | SYR4 | 2013–2019 |
| Lead | 5.8245 µg/L 39% of the EPA limit 15 µg/L
worst single sample: 6.1 µg/L | 2/30 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 967.5 µg/L 9.7% of the EPA limit 10000 µg/L
worst single sample: 990 µg/L | 2/2 | SYR4 | 2018–2019 |
| Chromium | 1 µg/L 1% of the EPA limit 100 µg/L | 1/7 | SYR4 | 2013–2019 |
| Monochloroacetic Acid | 1.4 µg/L No EPA limit set | 1/25 | SYR4 | 2012–2019 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Pine Grove Water
Is Pine Grove Water tap water safe to drink?
EPA monitoring detected 17 contaminants in Pine Grove Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Pine Grove Water's water?
EPA monitoring detected TTHM, Bromodichloromethane, Chloroform, Dichloroacetic Acid, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Pine Grove Water serve?
Pine Grove Water reports serving 620 people in West Virginia, per its EPA record.
Has Pine Grove Water had any water quality violations?
The EPA has 666 violations on file for Pine Grove Water, of which 37 are health-based (a contaminant limit or required treatment was breached) and 15 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.