← West Virginia

Tap water quality report

Lavalette Psd

EPA monitoring tested this supplier for 14 contaminants and detected 14. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
14
detected
7,455
people served
0
health-based violations
Water source
SWP
Ownership
Local government
Counties served
Wayne

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
12
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2017-01-01
MR Monitoring Resolved 2017-01-01
MR Monitoring Resolved 1998-01-01 → 1998-01-31
MR Monitoring Resolved 1998-01-01 → 1998-01-31
MR Monitoring Resolved 1998-01-01 → 1998-01-31
MR Monitoring Resolved 1997-12-01 → 1997-12-31
MR Monitoring Resolved 1997-12-01 → 1997-12-31
MR Monitoring Resolved 1997-12-01 → 1997-12-31
MR Monitoring Resolved 1997-12-01 → 1997-12-31
MR Monitoring Resolved 1991-05-01 → 1991-05-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
263.25 µg/L 20%
of the EPA limit 1300 µg/L
worst single sample: 344 µg/L
60/60 SYR4 2013–2019
Bromodichloromethane
30.005 µg/L
No EPA limit set
worst single sample: 38.2 µg/L
58/58 SYR4 2012–2019
Chloroform
63.765 µg/L
No EPA limit set
worst single sample: 78.5 µg/L
58/58 SYR4 2012–2019
Dibromochloromethane
16.23 µg/L
No EPA limit set
worst single sample: 22.4 µg/L
58/58 SYR4 2012–2019
TTHM
104.835 µg/L 131%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 116.42 µg/L
58/58 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
60.195 µg/L 100%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 73.4 µg/L
58/58 SYR4 2012–2019
Dichloroacetic Acid
27.7 µg/L
No EPA limit set
worst single sample: 40.5 µg/L
57/58 SYR4 2012–2019
Trichloroacetic Acid
22.34 µg/L
No EPA limit set
worst single sample: 27.3 µg/L
57/58 SYR4 2012–2019
Monochloroacetic Acid
6.0125 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
54/58 SYR4 2012–2019
Dibromoacetic Acid
5.3405 µg/L
No EPA limit set
worst single sample: 5.8 µg/L
38/57 SYR4 2012–2019
Bromoform
2.843 µg/L
No EPA limit set
worst single sample: 3.48 µg/L
23/58 SYR4 2012–2019
Lead
0.00088 mg/L 5.9%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
Monobromoacetic Acid
8.85 µg/L
No EPA limit set
worst single sample: 10.2 µg/L
13/58 SYR4 2012–2019
Lead
5.435 µg/L 36%
of the EPA limit 15 µg/L
worst single sample: 6.2 µg/L
10/60 SYR4 2013–2019

Utility contact

Contact
WEAVER, ROBERT W.
Phone
304-525-3771

Frequently asked questions about Lavalette Psd

Is Lavalette Psd tap water safe to drink?

EPA monitoring detected 14 contaminants in Lavalette Psd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lavalette Psd's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Lavalette Psd serve?

Lavalette Psd reports serving 7,455 people in West Virginia, per its EPA record.

Has Lavalette Psd had any water quality violations?

The EPA has 12 violations on file for Lavalette Psd, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.