Davis Water Works

EPA monitoring tested this supplier for 77 contaminants and detected 16. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
16
detected
952
people served
59
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Tucker

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

59
health-based violations
520
violations on file
4
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2025-11-25
TT Health-based Unaddressed 2025-11-25
TT Health-based Resolved 2015-08-01 → 2015-08-31
TT Health-based Resolved 2015-08-01 → 2015-08-31
TT Health-based Resolved 2015-08-01 → 2015-08-31
TT Health-based Resolved 2015-08-01 → 2015-08-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31
MCL Health-based Resolved 2015-07-01 → 2015-07-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Dichloroacetic Acid
40.29 µg/L
No EPA limit set
worst single sample: 57.9 µg/L
34/34 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
74.28 µg/L 124%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 132.4 µg/L
34/34 SYR4 2012–2019
Trichloroacetic Acid
37.24 µg/L
No EPA limit set
worst single sample: 71.8 µg/L
34/34 SYR4 2012–2019
Chloroform
73.12 µg/L
No EPA limit set
worst single sample: 77 µg/L
33/34 SYR4 2012–2019
TTHM
76.18 µg/L 95%
of the EPA limit 80 µg/L
worst single sample: 77.8 µg/L
33/34 SYR4 2012–2019
Bromodichloromethane
1.96 µg/L
No EPA limit set
worst single sample: 5 µg/L
20/34 SYR4 2012–2019
Copper
295.75 µg/L 23%
of the EPA limit 1300 µg/L
worst single sample: 519 µg/L
20/20 SYR4 2014–2017
Lead
0.0025 mg/L 17%
of the EPA limit 0.0150 mg/L
17/17 LCR 2026
Lead
17.1 µg/L 114%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 18 µg/L
10/20 SYR4 2014–2017
Dibromoacetic Acid
2.38 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
7/34 SYR4 2012–2019
Barium
12.55 µg/L 0.6%
of the EPA limit 2000 µg/L
worst single sample: 13 µg/L
4/8 SYR4 2012–2019
Monochloroacetic Acid
2.88 µg/L
No EPA limit set
worst single sample: 2.9 µg/L
3/34 SYR4 2012–2019
Nitrate
490 µg/L 4.9%
of the EPA limit 10000 µg/L
2/20 SYR4 2012–2019
Combined Radium (-226 And -228)
0.1940 pCi/L 3.9%
of the EPA limit 5 pCi/L
1/1 SYR4 2013
Di(2-ethylhexyl) Phthalate
0.9920 µg/L 17%
of the EPA limit 6 µg/L
1/3 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
0.2750 pCi/L 1.8%
of the EPA limit 15 pCi/L
1/2 SYR4 2013–2019
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDibromochloromethaneDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNitrate-NitriteNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
TOMSON, AL

Frequently asked questions about Davis Water Works

Is Davis Water Works tap water safe to drink?

EPA monitoring detected 16 contaminants in Davis Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Davis Water Works's water?

EPA monitoring detected Dichloroacetic Acid, Total Haloacetic Acids (HAA5), Trichloroacetic Acid, Chloroform, TTHM, and others. The full list with the level and data source for each is above.

How many people does Davis Water Works serve?

Davis Water Works reports serving 952 people in West Virginia, per its EPA record.

Has Davis Water Works had any water quality violations?

The EPA has 520 violations on file for Davis Water Works, of which 59 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.