Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2004-10-01 → 2004-10-31 |
| MCL | Health-based | Resolved | 2004-10-01 → 2004-10-31 |
| MCL | Health-based | Resolved | 2004-10-01 → 2004-10-31 |
| MCL | Health-based | Resolved | 2004-10-01 → 2004-10-31 |
| MCL | Health-based | Resolved | 2001-07-01 → 2001-07-31 |
| MCL | Health-based | Resolved | 2001-07-01 → 2001-07-31 |
| MCL | Health-based | Resolved | 2001-07-01 → 2001-07-31 |
| MCL | Health-based | Resolved | 2001-07-01 → 2001-07-31 |
| MR | Monitoring | Archived | 2024-01-01 → 2024-12-31 |
| MR | Monitoring | Archived | 2024-01-01 → 2024-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 113.95 µg/L 8.8% of the EPA limit 1300 µg/L
worst single sample: 140 µg/L | 30/31 | SYR4 | 2012–2018 |
| Lead | 7.11 µg/L 47% of the EPA limit 15 µg/L
worst single sample: 16 µg/L | 15/31 | SYR4 | 2012–2018 |
| Nitrate | 1600 µg/L 16% of the EPA limit 10000 µg/L | 12/12 | SYR4 | 2013–2019 |
| Lead | 0.0026 mg/L 17% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2024 |
| TTHM | 4.868 µg/L 6.1% of the EPA limit 80 µg/L
worst single sample: 5.4 µg/L | 9/9 | SYR4 | 2012–2019 |
| Dibromochloromethane | 1.791 µg/L No EPA limit set
worst single sample: 1.84 µg/L | 8/9 | SYR4 | 2012–2019 |
| Bromodichloromethane | 1.045 µg/L No EPA limit set
worst single sample: 1.1 µg/L | 6/9 | SYR4 | 2012–2019 |
| Bromoform | 1.5125 µg/L No EPA limit set
worst single sample: 1.55 µg/L | 6/9 | SYR4 | 2012–2019 |
| Barium | 65.43 µg/L 3.3% of the EPA limit 2000 µg/L
worst single sample: 65.8 µg/L | 3/3 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 2.801 µg/L 4.7% of the EPA limit 60 µg/L
worst single sample: 2.98 µg/L | 3/9 | SYR4 | 2012–2019 |
| Chloroform | 1.156 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 2/9 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 1.5605 µg/L No EPA limit set
worst single sample: 1.58 µg/L | 2/9 | SYR4 | 2012–2019 |
| 2,4-D | 0.2710 µg/L 0.4% of the EPA limit 70 µg/L | 1/3 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 1.39 µg/L No EPA limit set | 1/9 | SYR4 | 2012–2019 |
| Fluoride | 130 µg/L 3.3% of the EPA limit 4000 µg/L | 1/3 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 2.32 pCi/L 15% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2013 |
| Nitrate-Nitrite | 1960 µg/L 20% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2019 |
| Nitrite | 360 µg/L 36% of the EPA limit 1000 µg/L | 1/1 | SYR4 | 2019 |
| Thallium, Total | 0.3000 µg/L 15% of the EPA limit 2 µg/L | 1/3 | SYR4 | 2013–2019 |
57 contaminants tested, none detected
Utility contact
Frequently asked questions about Carpendale, Town of
Is Carpendale, Town of tap water safe to drink?
EPA monitoring detected 19 contaminants in Carpendale, Town of's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Carpendale, Town of's water?
EPA monitoring detected Copper, Lead, Nitrate, Lead, TTHM, and others. The full list with the level and data source for each is above.
How many people does Carpendale, Town of serve?
Carpendale, Town of reports serving 937 people in West Virginia, per its EPA record.
Has Carpendale, Town of had any water quality violations?
The EPA has 68 violations on file for Carpendale, Town of, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.