Tap water quality report

Mason Co Psd-Lakin Dist

EPA monitoring tested this supplier for 75 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

75
contaminants tested
21
detected
4,296
people served
7
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Mason

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

7
health-based violations
86
violations on file
2
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2026-03-13
MCL Health-based Resolved 1998-10-01 → 1998-12-31
MCL Health-based Resolved 1998-10-01 → 1998-12-31
MCL Health-based Resolved 1998-10-01 → 1998-12-31
MCL Health-based Resolved 1998-07-01 → 1998-09-30
MCL Health-based Resolved 1998-07-01 → 1998-09-30
MCL Health-based Resolved 1998-07-01 → 1998-09-30
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31
MR Monitoring Archived 2023-01-01 → 2025-12-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
5710 µg/L 57%
of the EPA limit 10000 µg/L
worst single sample: 6060 µg/L
42/42 SYR4 2012–2019
Copper
237.4 µg/L 18%
of the EPA limit 1300 µg/L
worst single sample: 294 µg/L
30/30 SYR4 2013–2019
Lead
9.775 µg/L 65%
of the EPA limit 15 µg/L
worst single sample: 13.6 µg/L
30/30 SYR4 2013–2019
Lead
0.0045 mg/L 30%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Bromoform
3.086 µg/L
No EPA limit set
worst single sample: 3.1 µg/L
8/8 SYR4 2012–2019
Dibromoacetic Acid
2.6305 µg/L
No EPA limit set
worst single sample: 2.83 µg/L
8/8 SYR4 2012–2019
Dibromochloromethane
3.364 µg/L
No EPA limit set
worst single sample: 3.91 µg/L
8/8 SYR4 2012–2019
TTHM
12.6565 µg/L 16%
of the EPA limit 80 µg/L
worst single sample: 15.6 µg/L
8/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
8.1055 µg/L 14%
of the EPA limit 60 µg/L
worst single sample: 8.97 µg/L
8/8 SYR4 2012–2019
Bromodichloromethane
6.615 µg/L
No EPA limit set
worst single sample: 8.22 µg/L
6/8 SYR4 2012–2019
Chloroform
2.189 µg/L
No EPA limit set
worst single sample: 2.45 µg/L
4/8 SYR4 2012–2019
Barium
53.61 µg/L 2.7%
of the EPA limit 2000 µg/L
worst single sample: 53.9 µg/L
3/3 SYR4 2013–2019
Dichloroacetic Acid
2.573 µg/L
No EPA limit set
worst single sample: 2.7 µg/L
3/8 SYR4 2012–2019
Fluoride
147 µg/L 3.7%
of the EPA limit 4000 µg/L
worst single sample: 150 µg/L
3/3 SYR4 2013–2019
Monochloroacetic Acid
5.361 µg/L
No EPA limit set
worst single sample: 5.58 µg/L
2/8 SYR4 2012–2019
Antimony, Total
0.4000 µg/L 6.7%
of the EPA limit 6 µg/L
1/3 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
1.23 pCi/L 8.2%
of the EPA limit 15 pCi/L
1/2 SYR4 2013–2019
Nitrite
350 µg/L 35%
of the EPA limit 1000 µg/L
1/1 SYR4 2019
Selenium
1.7 µg/L 3.4%
of the EPA limit 50 µg/L
1/3 SYR4 2013–2019
Thallium, Total
0.2000 µg/L 10%
of the EPA limit 2 µg/L
1/3 SYR4 2013–2019
Trichloroacetic Acid
1 µg/L
No EPA limit set
1/8 SYR4 2012–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Frequently asked questions about Mason Co Psd-Lakin Dist

Is Mason Co Psd-Lakin Dist tap water safe to drink?

EPA monitoring detected 21 contaminants in Mason Co Psd-Lakin Dist's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Mason Co Psd-Lakin Dist's water?

EPA monitoring detected Nitrate, Copper, Lead, Lead, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Mason Co Psd-Lakin Dist serve?

Mason Co Psd-Lakin Dist reports serving 4,296 people, per its EPA record.

Has Mason Co Psd-Lakin Dist had any water quality violations?

The EPA has 86 violations on file for Mason Co Psd-Lakin Dist, of which 7 are health-based (a contaminant limit or required treatment was breached) and 2 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.