Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Archived | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Archived | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Archived | 2025-01-01 → 2025-03-31 |
| MCL | Health-based | Archived | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Archived | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Archived | 2024-10-01 → 2024-12-31 |
| MCL | Health-based | Archived | 2024-10-01 → 2024-12-31 |
| TT | Health-based | Unaddressed | 2023-10-15 |
| TT | Health-based | Unaddressed | 2023-10-15 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 128 µg/L 9.8% of the EPA limit 1300 µg/L
worst single sample: 604 µg/L | 61/61 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 70.06 µg/L 117% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 95 µg/L | 54/54 | SYR4 | 2012–2019 |
| TTHM | 120 µg/L 150% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 130 µg/L | 53/53 | SYR4 | 2012–2019 |
| Bromodichloromethane | 17.34 µg/L No EPA limit set
worst single sample: 22 µg/L | 52/52 | SYR4 | 2012–2019 |
| Chloroform | 98.35 µg/L No EPA limit set
worst single sample: 104 µg/L | 52/52 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 33.15 µg/L No EPA limit set
worst single sample: 46 µg/L | 52/52 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 38.825 µg/L No EPA limit set
worst single sample: 43 µg/L | 50/52 | SYR4 | 2012–2019 |
| Dibromochloromethane | 4.01 µg/L No EPA limit set
worst single sample: 5 µg/L | 40/52 | SYR4 | 2012–2019 |
| Nitrate | 404 µg/L 4% of the EPA limit 10000 µg/L | 18/18 | SYR4 | 2012–2019 |
| Lead | 2.2 µg/L 15% of the EPA limit 15 µg/L
worst single sample: 3 µg/L | 17/61 | SYR4 | 2013–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 14/14 | LCR | 2025 |
| Monochloroacetic Acid | 6.02 µg/L No EPA limit set
worst single sample: 8 µg/L | 13/52 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.78 µg/L No EPA limit set
worst single sample: 2 µg/L | 12/52 | SYR4 | 2012–2019 |
| Fluoride | 1209 µg/L 30% of the EPA limit 4000 µg/L
worst single sample: 1330 µg/L | 12/12 | SYR4 | 2012–2019 |
| Barium | 47.49 µg/L 2.4% of the EPA limit 2000 µg/L
worst single sample: 49.8 µg/L | 8/8 | SYR4 | 2012–2019 |
| Selenium | 1.018 µg/L 2% of the EPA limit 50 µg/L
worst single sample: 1.032 µg/L | 6/8 | SYR4 | 2012–2019 |
| Cyanide | 84.4 µg/L 42% of the EPA limit 200 µg/L
worst single sample: 97.3 µg/L | 5/8 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 1.0895 µg/L No EPA limit set
worst single sample: 1.1 µg/L | 4/52 | SYR4 | 2012–2019 |
| Chromium | 1.855 µg/L 1.9% of the EPA limit 100 µg/L
worst single sample: 1.908 µg/L | 3/8 | SYR4 | 2012–2019 |
| Antimony, Total | 0.2298 µg/L 3.8% of the EPA limit 6 µg/L
worst single sample: 0.2320 µg/L | 2/8 | SYR4 | 2012–2019 |
| Bromoform | 1.92515 µg/L No EPA limit set
worst single sample: 2 µg/L | 2/52 | SYR4 | 2012–2019 |
| Beryllium, Total | 0.0172 µg/L 0.4% of the EPA limit 4 µg/L | 1/8 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 0.0117 pCi/L 0.2% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2013 |
| Nitrate-Nitrite | 210 µg/L 2.1% of the EPA limit 10000 µg/L | 1/1 | SYR4 | 2016 |
52 contaminants tested, none detected
Frequently asked questions about Logan Co Psd-Greenville
Is Logan Co Psd-Greenville tap water safe to drink?
EPA monitoring detected 24 contaminants in Logan Co Psd-Greenville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Logan Co Psd-Greenville's water?
EPA monitoring detected Copper, Total Haloacetic Acids (HAA5), TTHM, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.
How many people does Logan Co Psd-Greenville serve?
Logan Co Psd-Greenville reports serving 3,611 people, per its EPA record.
Has Logan Co Psd-Greenville had any water quality violations?
The EPA has 378 violations on file for Logan Co Psd-Greenville, of which 48 are health-based (a contaminant limit or required treatment was breached) and 61 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.