← West Virginia

Tap water quality report

Ravenswood Municipal Water Works

EPA monitoring tested this supplier for 74 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
18
detected
5,047
people served
37
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Jackson

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

37
health-based violations
469
violations on file
7
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-05-25
TT Health-based Resolved 2024-05-25
TT Health-based Resolved 2024-05-25
TT Health-based Resolved 2024-05-25
TT Health-based Unaddressed 2024-04-01
TT Health-based Unaddressed 2024-04-01
TT Health-based Unaddressed 2024-04-01
TT Health-based Unaddressed 2024-04-01
TT Health-based Unaddressed 2024-04-01
TT Health-based Unaddressed 2024-04-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Tetrachloroethylene
5.19 µg/L 104%
of the EPA limit, at the 95th percentile of samples — 5 µg/L
worst single sample: 10 µg/L
121/176 SYR4 2012–2019
Copper
233.4 µg/L 18%
of the EPA limit 1300 µg/L
worst single sample: 633 µg/L
53/60 SYR4 2012–2018
Lead
10.675 µg/L 71%
of the EPA limit 15 µg/L
worst single sample: 108 µg/L
38/60 SYR4 2012–2018
Nitrate
5488 µg/L 55%
of the EPA limit 10000 µg/L
worst single sample: 5530 µg/L
28/28 SYR4 2012–2019
Lead
0.0033 mg/L 22%
of the EPA limit 0.0150 mg/L
19/19 LCR 2025
Bromodichloromethane
1.758 µg/L
No EPA limit set
worst single sample: 1.8 µg/L
8/8 SYR4 2012–2019
Dibromochloromethane
2.151 µg/L
No EPA limit set
worst single sample: 2.34 µg/L
8/8 SYR4 2012–2019
TTHM
5.6915 µg/L 7.1%
of the EPA limit 80 µg/L
worst single sample: 6.22 µg/L
8/8 SYR4 2012–2019
Bromoform
1.0375 µg/L
No EPA limit set
worst single sample: 1.05 µg/L
6/8 SYR4 2012–2019
Chloroform
1.0555 µg/L
No EPA limit set
worst single sample: 1.06 µg/L
4/8 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
2.353 µg/L 3.9%
of the EPA limit 60 µg/L
worst single sample: 2.49 µg/L
3/8 SYR4 2012–2019
Barium
55.085 µg/L 2.8%
of the EPA limit 2000 µg/L
worst single sample: 55.1 µg/L
2/2 SYR4 2013–2016
Fluoride
407.5 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 410 µg/L
2/2 SYR4 2013–2016
Monochloroacetic Acid
1.272 µg/L
No EPA limit set
worst single sample: 1.28 µg/L
2/8 SYR4 2012–2019
Chromium
1.2 µg/L 1.2%
of the EPA limit 100 µg/L
1/2 SYR4 2013–2016
Dibromoacetic Acid
0.9580 µg/L
No EPA limit set
1/8 SYR4 2012–2019
Dichloroacetic Acid
1.22 µg/L
No EPA limit set
1/8 SYR4 2012–2019
Selenium
1.2 µg/L 2.4%
of the EPA limit 50 µg/L
1/2 SYR4 2013–2016
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidOxamylPentachlorophenolPicloramSimazineStyreneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MILLER, JOSH
Phone
304-273-4142

Frequently asked questions about Ravenswood Municipal Water Works

Is Ravenswood Municipal Water Works tap water safe to drink?

EPA monitoring detected 18 contaminants in Ravenswood Municipal Water Works's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ravenswood Municipal Water Works's water?

EPA monitoring detected Tetrachloroethylene, Copper, Lead, Nitrate, Lead, and others. The full list with the level and data source for each is above.

How many people does Ravenswood Municipal Water Works serve?

Ravenswood Municipal Water Works reports serving 5,047 people in West Virginia, per its EPA record.

Has Ravenswood Municipal Water Works had any water quality violations?

The EPA has 469 violations on file for Ravenswood Municipal Water Works, of which 37 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.