Tap water quality report

Berkeley County Pswd-Potomac River

EPA monitoring tested this supplier for 77 contaminants and detected 22. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

77
contaminants tested
22
detected
69,372
people served
48
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Berkeley

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

48
health-based violations
97
violations on file
7
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2009-09-01 → 2009-09-30
MCL Health-based Resolved 2009-09-01 → 2009-09-30
MCL Health-based Resolved 2009-09-01 → 2009-09-30
MCL Health-based Resolved 2009-09-01 → 2009-09-30
MCL Health-based Resolved 2007-12-01 → 2007-12-31
MCL Health-based Resolved 2007-12-01 → 2007-12-31
MCL Health-based Resolved 2007-12-01 → 2007-12-31
MCL Health-based Resolved 2007-12-01 → 2007-12-31
MCL Health-based Resolved 2005-07-01 → 2005-09-30
MCL Health-based Resolved 2005-07-01 → 2005-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Dichloroacetic Acid
26.963 µg/L
No EPA limit set
worst single sample: 31.2 µg/L
134/134 SYR4 2012–2019
Trichloroacetic Acid
28.6275 µg/L
No EPA limit set
worst single sample: 33.56 µg/L
134/134 SYR4 2012–2019
Bromodichloromethane
33.518 µg/L
No EPA limit set
worst single sample: 45.26 µg/L
133/134 SYR4 2012–2019
Monobromoacetic Acid
10.11 µg/L
No EPA limit set
worst single sample: 12.43 µg/L
133/134 SYR4 2012–2019
TTHM
102.224 µg/L 128%
of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 213.88 µg/L
133/134 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
62.652 µg/L 104%
of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 73.2 µg/L
133/134 SYR4 2012–2019
Chloroform
55.5435 µg/L
No EPA limit set
worst single sample: 153.6 µg/L
132/134 SYR4 2012–2019
Dibromochloromethane
22.09 µg/L
No EPA limit set
worst single sample: 31.4 µg/L
132/134 SYR4 2012–2019
Dibromoacetic Acid
5.638 µg/L
No EPA limit set
worst single sample: 6.64 µg/L
84/134 SYR4 2012–2019
Copper
90.95 µg/L 7%
of the EPA limit 1300 µg/L
worst single sample: 309 µg/L
52/60 SYR4 2014–2017
Bromoform
5.056 µg/L
No EPA limit set
worst single sample: 12.57 µg/L
42/134 SYR4 2012–2019
Nitrate
1895 µg/L 19%
of the EPA limit 10000 µg/L
worst single sample: 1990 µg/L
26/28 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
21/21 LCR 2024
Lead
16.75 µg/L 112%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 22 µg/L
16/60 SYR4 2014–2017
Barium
42.9 µg/L 2.1%
of the EPA limit 2000 µg/L
worst single sample: 45 µg/L
7/8 SYR4 2012–2019
Fluoride
1078 µg/L 27%
of the EPA limit 4000 µg/L
worst single sample: 1120 µg/L
7/8 SYR4 2012–2019
Gross Alpha, Excl. Radon And U
6.06455 pCi/L 40%
of the EPA limit 15 pCi/L
worst single sample: 6.38 pCi/L
2/2 SYR4 2013–2019
Antimony, Total
4 µg/L 67%
of the EPA limit 6 µg/L
1/8 SYR4 2012–2019
Chromium
1.4 µg/L 1.4%
of the EPA limit 100 µg/L
1/8 SYR4 2012–2019
Di(2-ethylhexyl) Phthalate
0.9980 µg/L 17%
of the EPA limit 6 µg/L
1/5 SYR4 2013–2019
Monochloroacetic Acid
2 µg/L
No EPA limit set
1/134 SYR4 2012–2019
Nitrate-Nitrite
1330 µg/L 13%
of the EPA limit 10000 µg/L
1/1 SYR4 2019
55 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined Radium (-226 And -228)DichloromethaneDalaponDi(2-ethylhexyl) AdipateDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Frequently asked questions about Berkeley County Pswd-Potomac River

Is Berkeley County Pswd-Potomac River tap water safe to drink?

EPA monitoring detected 22 contaminants in Berkeley County Pswd-Potomac River's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Berkeley County Pswd-Potomac River's water?

EPA monitoring detected Dichloroacetic Acid, Trichloroacetic Acid, Bromodichloromethane, Monobromoacetic Acid, TTHM, and others. The full list with the level and data source for each is above.

How many people does Berkeley County Pswd-Potomac River serve?

Berkeley County Pswd-Potomac River reports serving 69,372 people, per its EPA record.

Has Berkeley County Pswd-Potomac River had any water quality violations?

The EPA has 97 violations on file for Berkeley County Pswd-Potomac River, of which 48 are health-based (a contaminant limit or required treatment was breached) and 7 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.