Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 1997-06-01 → 1997-06-30 |
| MCL | Health-based | Resolved | 1997-06-01 → 1997-06-30 |
| MCL | Health-based | Resolved | 1997-06-01 → 1997-06-30 |
| MCL | Health-based | Resolved | 1997-06-01 → 1997-06-30 |
| MR | Monitoring | Unaddressed | 2012-01-01 |
| MR | Monitoring | Unaddressed | 2012-01-01 |
| MR | Monitoring | Unaddressed | 2012-01-01 |
| MR | Monitoring | Resolved | 2009-10-01 → 2009-12-31 |
| MR | Monitoring | Resolved | 2009-10-01 → 2009-12-31 |
| MR | Monitoring | Resolved | 2009-10-01 → 2009-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Fluoride | 777.3 µg/L 19% of the EPA limit 4000 µg/L
worst single sample: 1030 µg/L | 107/207 | SYR4 | 2012–2019 |
| Nitrate | 3800 µg/L 38% of the EPA limit 10000 µg/L
worst single sample: 4200 µg/L | 50/82 | SYR4 | 2012–2019 |
| Copper | 110 µg/L 8.5% of the EPA limit 1300 µg/L
worst single sample: 150 µg/L | 40/40 | SYR4 | 2014–2017 |
| Lead | 8.6 µg/L 57% of the EPA limit 15 µg/L
worst single sample: 14 µg/L | 37/40 | SYR4 | 2014–2017 |
| Lead | 0.0130 mg/L 87% of the EPA limit 0.0150 mg/L | 17/17 | LCR | 2020 |
| Barium | 66.2 µg/L 3.3% of the EPA limit 2000 µg/L
worst single sample: 74 µg/L | 14/14 | SYR4 | 2014–2019 |
| TTHM | 12.876 µg/L 16% of the EPA limit 80 µg/L
worst single sample: 13.8 µg/L | 13/13 | SYR4 | 2013–2019 |
| Bromodichloromethane | 4.08 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 12/15 | SYR4 | 2013–2019 |
| Chloroform | 5.35 µg/L No EPA limit set
worst single sample: 5.9 µg/L | 12/15 | SYR4 | 2013–2019 |
| Dibromochloromethane | 3.27 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 12/15 | SYR4 | 2013–2019 |
| Total Haloacetic Acids (HAA5) | 1.9865 µg/L 3.3% of the EPA limit 60 µg/L
worst single sample: 2.41 µg/L | 12/13 | SYR4 | 2013–2019 |
| Nitrate-Nitrite | 3460 µg/L 35% of the EPA limit 10000 µg/L
worst single sample: 3500 µg/L | 9/14 | SYR4 | 2014–2019 |
| Combined Radium (-226 And -228) | 3.886 pCi/L 78% of the EPA limit 5 pCi/L
worst single sample: 4.25 pCi/L | 8/8 | SYR4 | 2014–2017 |
| Tetrachloroethylene | 1.765 µg/L 35% of the EPA limit 5 µg/L
worst single sample: 1.8 µg/L | 8/27 | SYR4 | 2012–2019 |
| Arsenic | 8 µg/L 80% of the EPA limit 10 µg/L | 6/14 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 0.7575 µg/L No EPA limit set
worst single sample: 0.8000 µg/L | 6/13 | SYR4 | 2013–2019 |
| Bromoform | 1.5 µg/L No EPA limit set | 3/14 | SYR4 | 2013–2019 |
| Dichloroacetic Acid | 0.6890 µg/L No EPA limit set
worst single sample: 0.7000 µg/L | 3/13 | SYR4 | 2013–2019 |
| Gross Alpha, Excl. Radon And U | 4.198 pCi/L 28% of the EPA limit 15 pCi/L
worst single sample: 4.25 pCi/L | 2/2 | SYR4 | 2014–2017 |
| Chromium | 5.8 µg/L 5.8% of the EPA limit 100 µg/L | 1/14 | SYR4 | 2014–2019 |
| Combined Uranium | 0.6050 µg/L 2% of the EPA limit 30 µg/L | 1/1 | SYR4 | 2019 |
54 contaminants tested, none detected
Utility contact
Frequently asked questions about New London Waterworks
Is New London Waterworks tap water safe to drink?
EPA monitoring detected 21 contaminants in New London Waterworks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in New London Waterworks's water?
EPA monitoring detected Fluoride, Nitrate, Copper, Lead, Lead, and others. The full list with the level and data source for each is above.
How many people does New London Waterworks serve?
New London Waterworks reports serving 7,187 people in Wisconsin, per its EPA record.
Has New London Waterworks had any water quality violations?
The EPA has 443 violations on file for New London Waterworks, of which 4 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.