Tap water quality report

Clinton Waterworks

EPA monitoring tested this supplier for 104 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
18
detected
2,119
people served
5
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Rock

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
219
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2008-10-01 → 2009-10-21
MCL Health-based Resolved 2008-10-01 → 2009-10-21
MCL Health-based Resolved 2008-10-01 → 2009-10-21
MCL Health-based Resolved 2008-10-01 → 2009-10-21
MCL Health-based Resolved 2008-10-01 → 2009-10-21
MR Monitoring Resolved 2009-04-01 → 2009-06-30
MR Monitoring Resolved 2009-04-01 → 2009-06-30
MR Monitoring Resolved 2009-04-01 → 2009-06-30
MR Monitoring Resolved 2009-04-01 → 2009-06-30
MR Monitoring Resolved 2009-04-01 → 2009-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
1009.5 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 2000 µg/L
68/132 SYR4 2012–2017
Thallium, Total
1.54 µg/L 77%
of the EPA limit 2 µg/L
worst single sample: 1.7 µg/L
33/33 SYR4 2012–2019
Copper
561 µg/L 43%
of the EPA limit 1300 µg/L
worst single sample: 770 µg/L
20/20 SYR4 2014–2017
Lead
6.95 µg/L 46%
of the EPA limit 15 µg/L
worst single sample: 20 µg/L
16/20 SYR4 2014–2017
Lead
0.00029 mg/L 1.9%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Chloroform
3.6 µg/L
No EPA limit set
worst single sample: 3.7 µg/L
11/11 SYR4 2013–2019
TTHM
5.349 µg/L 6.7%
of the EPA limit 80 µg/L
worst single sample: 5.61 µg/L
10/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.541 µg/L 2.6%
of the EPA limit 60 µg/L
worst single sample: 1.55 µg/L
7/8 SYR4 2013–2019
Bromodichloromethane
1.3 µg/L
No EPA limit set
6/11 SYR4 2013–2019
Nitrate
120 µg/L 1.2%
of the EPA limit 10000 µg/L
6/24 SYR4 2012–2019
Barium
294 µg/L 15%
of the EPA limit 2000 µg/L
worst single sample: 300 µg/L
4/4 SYR4 2014–2017
Combined Radium (-226 And -228)
3.4345 pCi/L 69%
of the EPA limit 5 pCi/L
worst single sample: 3.55 pCi/L
4/4 SYR4 2014–2017
Trichloroacetic Acid
0.7480 µg/L
No EPA limit set
worst single sample: 0.7600 µg/L
4/8 SYR4 2013–2019
Dichloroacetic Acid
1.066 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
3/8 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
6.058 pCi/L 40%
of the EPA limit 15 pCi/L
worst single sample: 6.25 pCi/L
3/3 SYR4 2014–2017
Arsenic
1.98 µg/L 20%
of the EPA limit 10 µg/L
worst single sample: 2 µg/L
2/4 SYR4 2014–2017
Nitrate-Nitrite
167 µg/L 1.7%
of the EPA limit 10000 µg/L
worst single sample: 170 µg/L
2/4 SYR4 2014–2017
Dibromochloromethane
0.6100 µg/L
No EPA limit set
1/11 SYR4 2013–2019
86 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAtrazineBhc-GammaBenzeneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDibromoacetic AcidDinosebDiquatEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Frequently asked questions about Clinton Waterworks

Is Clinton Waterworks tap water safe to drink?

EPA monitoring detected 18 contaminants in Clinton Waterworks's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Clinton Waterworks's water?

EPA monitoring detected Fluoride, Thallium, Total, Copper, Lead, Lead, and others. The full list with the level and data source for each is above.

How many people does Clinton Waterworks serve?

Clinton Waterworks reports serving 2,119 people in Wisconsin, per its EPA record.

Has Clinton Waterworks had any water quality violations?

The EPA has 219 violations on file for Clinton Waterworks, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.