← Wisconsin

Tap water quality report

Fitchburg Utility Dist 1 South

EPA monitoring tested this supplier for 74 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
20
detected
350
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Dane

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
10
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31
MR Monitoring Resolved 2009-01-01 → 2009-03-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
1224.5 µg/L 31%
of the EPA limit 4000 µg/L
worst single sample: 1370 µg/L
98/196 SYR4 2012–2019
Nitrate
5300 µg/L 53%
of the EPA limit 10000 µg/L
worst single sample: 6200 µg/L
36/36 SYR4 2012–2019
Lead
0.0052 mg/L 34%
of the EPA limit 0.0150 mg/L
14/14 LCR 2023
Copper
255.05 µg/L 20%
of the EPA limit 1300 µg/L
worst single sample: 260 µg/L
10/10 SYR4 2014–2017
Bromodichloromethane
3.45 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
6/8 SYR4 2014–2019
Chloroform
4.85 µg/L
No EPA limit set
worst single sample: 5 µg/L
6/8 SYR4 2014–2019
Dichloroacetic Acid
2.15 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
6/6 SYR4 2014–2019
Lead
4.505 µg/L 30%
of the EPA limit 15 µg/L
worst single sample: 4.9 µg/L
6/10 SYR4 2014–2017
TTHM
10.8225 µg/L 14%
of the EPA limit 80 µg/L
worst single sample: 11.03 µg/L
6/6 SYR4 2014–2019
Total Haloacetic Acids (HAA5)
3.6125 µg/L 6%
of the EPA limit 60 µg/L
worst single sample: 3.73 µg/L
6/6 SYR4 2014–2019
Dibromochloromethane
2.22 µg/L
No EPA limit set
worst single sample: 2.3 µg/L
5/8 SYR4 2014–2019
Barium
60.35 µg/L 3%
of the EPA limit 2000 µg/L
worst single sample: 62 µg/L
4/4 SYR4 2014–2017
Dibromoacetic Acid
0.9850 µg/L
No EPA limit set
worst single sample: 1 µg/L
4/6 SYR4 2014–2019
Nitrate-Nitrite
4976 µg/L 50%
of the EPA limit 10000 µg/L
worst single sample: 5000 µg/L
4/4 SYR4 2014–2017
Trichloroacetic Acid
0.5290 µg/L
No EPA limit set
worst single sample: 0.5300 µg/L
3/6 SYR4 2014–2019
Chromium
1.87 µg/L 1.9%
of the EPA limit 100 µg/L
worst single sample: 1.9 µg/L
2/4 SYR4 2014–2017
Combined Radium (-226 And -228)
0.2680 pCi/L 5.4%
of the EPA limit 5 pCi/L
worst single sample: 0.2700 pCi/L
2/2 SYR4 2014
Gross Alpha, Excl. Radon And U
2.004 pCi/L 13%
of the EPA limit 15 pCi/L
worst single sample: 2.04 pCi/L
2/2 SYR4 2014
Bromoform
0.9300 µg/L
No EPA limit set
1/8 SYR4 2014–2019
Monobromoacetic Acid
0.3100 µg/L
No EPA limit set
1/6 SYR4 2014–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneDichloromethaneDalaponDinosebDiquatEndothallEndrinEthylbenzeneGlyphosateHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Frequently asked questions about Fitchburg Utility Dist 1 South

Is Fitchburg Utility Dist 1 South tap water safe to drink?

EPA monitoring detected 20 contaminants in Fitchburg Utility Dist 1 South's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Fitchburg Utility Dist 1 South's water?

EPA monitoring detected Fluoride, Nitrate, Lead, Copper, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Fitchburg Utility Dist 1 South serve?

Fitchburg Utility Dist 1 South reports serving 350 people in Wisconsin, per its EPA record.

Has Fitchburg Utility Dist 1 South had any water quality violations?

The EPA has 10 violations on file for Fitchburg Utility Dist 1 South, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.