Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Archived | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Archived | 1998-08-01 → 1998-08-31 |
| MCL | Health-based | Archived | 1993-09-01 → 1993-09-30 |
| Other | Monitoring | Resolved | 2016-07-01 |
| MR | Monitoring | Archived | 2008-04-01 → 2008-06-30 |
| MR | Monitoring | Archived | 2008-04-01 → 2008-06-30 |
| MR | Monitoring | Archived | 2008-04-01 → 2008-06-30 |
| MR | Monitoring | Resolved | 2006-10-01 → 2006-12-31 |
| MR | Monitoring | Resolved | 2006-10-01 → 2006-12-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 2640 µg/L 26% of the EPA limit 10000 µg/L
worst single sample: 2720 µg/L | 48/132 | SYR4 | 2012–2019 |
| TTHM | 11.475 µg/L 14% of the EPA limit 80 µg/L
worst single sample: 19.3 µg/L | 46/46 | SYR4 | 2012–2019 |
| Chloroform | 7.06 µg/L No EPA limit set
worst single sample: 12.7 µg/L | 39/80 | SYR4 | 2012–2019 |
| Dibromochloromethane | 2 µg/L No EPA limit set
worst single sample: 2.5 µg/L | 39/77 | SYR4 | 2012–2019 |
| Bromodichloromethane | 3.33 µg/L No EPA limit set
worst single sample: 4.6 µg/L | 38/74 | SYR4 | 2012–2019 |
| Bromoform | 0.9000 µg/L No EPA limit set
worst single sample: 1.1 µg/L | 21/79 | SYR4 | 2012–2019 |
| Lead | 0.0020 mg/L 13% of the EPA limit 0.0150 mg/L | 18/18 | LCR | 2025 |
| Dichloroacetic Acid | 2.6 µg/L No EPA limit set | 12/71 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 5.7 µg/L 9.5% of the EPA limit 60 µg/L
worst single sample: 6.8 µg/L | 12/69 | SYR4 | 2012–2018 |
| Nitrate-Nitrite | 1734 µg/L 17% of the EPA limit 10000 µg/L
worst single sample: 1980 µg/L | 5/13 | SYR4 | 2013–2019 |
| Arsenic | 7.34 µg/L 73% of the EPA limit 10 µg/L
worst single sample: 8 µg/L | 4/13 | SYR4 | 2013–2019 |
| Trichloroacetic Acid | 3.3 µg/L No EPA limit set
worst single sample: 3.4 µg/L | 3/71 | SYR4 | 2012–2019 |
| Chromium | 9.85 µg/L 9.9% of the EPA limit 100 µg/L
worst single sample: 10 µg/L | 2/13 | SYR4 | 2013–2019 |
| Dibromoacetic Acid | 1 µg/L No EPA limit set | 1/71 | SYR4 | 2012–2019 |
88 contaminants tested, none detected
Utility contact
Frequently asked questions about Silverdale Water Dist 16
Is Silverdale Water Dist 16 tap water safe to drink?
EPA monitoring detected 14 contaminants in Silverdale Water Dist 16's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Silverdale Water Dist 16's water?
EPA monitoring detected Nitrate, TTHM, Chloroform, Dibromochloromethane, Bromodichloromethane, and others. The full list with the level and data source for each is above.
How many people does Silverdale Water Dist 16 serve?
Silverdale Water Dist 16 reports serving 35,163 people in Washington, per its EPA record.
Has Silverdale Water Dist 16 had any water quality violations?
The EPA has 98 violations on file for Silverdale Water Dist 16, of which 4 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.