Tap water quality report

Parkland Light & Water Company

EPA monitoring tested this supplier for 104 contaminants and detected 21. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

104
contaminants tested
21
detected
33,775
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Pierce

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
76
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Archived 2025-01-01 → 2025-12-31
MR Monitoring Archived 2025-01-01 → 2025-12-31
Other Monitoring Resolved 2016-07-01
MR Monitoring Resolved 2015-01-01 → 2015-12-31
MR Monitoring Archived 2008-01-01 → 2009-09-30
MR Monitoring Archived 2008-01-01 → 2009-09-30
MR Monitoring Archived 2008-01-01 → 2009-09-30
MR Monitoring Archived 2008-01-01 → 2009-09-30
MR Monitoring Archived 2008-01-01 → 2009-09-30
MR Monitoring Archived 2008-01-01 → 2009-09-30

PFAS detected

PFAS are industrial “forever chemicals”. These are the EPA's latest nationwide test results (2023–2025).
ContaminantMaxDetection ratePeriod
PFOS 0.0138 µg/L 4/10 2024
PFBS 0.0075 µg/L 3/10 2024
PFHXS 0.0047 µg/L 3/10 2024
PFOA 0.0062 µg/L 3/10 2024
Pfpea 0.0055 µg/L 2/10 2024
Pfhxa 0.0036 µg/L 1/10 2024

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2400 µg/L 24%
of the EPA limit 10000 µg/L
worst single sample: 2600 µg/L
110/124 SYR4 2012–2019
TTHM
15.9815 µg/L 20%
of the EPA limit 80 µg/L
worst single sample: 16.86 µg/L
42/42 SYR4 2012–2019
Chloroform
10.869 µg/L
No EPA limit set
worst single sample: 11.36 µg/L
38/62 SYR4 2012–2019
Bromodichloromethane
4.4 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
35/64 SYR4 2012–2019
Dibromochloromethane
1.905 µg/L
No EPA limit set
worst single sample: 2.5 µg/L
34/64 SYR4 2012–2019
Dichloroacetic Acid
4.8 µg/L
No EPA limit set
16/46 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
13.3125 µg/L 22%
of the EPA limit 60 µg/L
worst single sample: 13.65 µg/L
16/46 SYR4 2012–2019
Trichloroacetic Acid
8.5125 µg/L
No EPA limit set
worst single sample: 8.85 µg/L
16/46 SYR4 2012–2019
Fluoride
950 µg/L 24%
of the EPA limit 4000 µg/L
worst single sample: 1000 µg/L
11/11 SYR4 2012
Lead
0.0024 mg/L 16%
of the EPA limit 0.0150 mg/L
11/11 LCR 2023
Nitrate-Nitrite
2120 µg/L 21%
of the EPA limit 10000 µg/L
worst single sample: 2200 µg/L
9/11 SYR4 2012
Arsenic
4.95 µg/L 50%
of the EPA limit 10 µg/L
worst single sample: 5 µg/L
2/11 SYR4 2012
Bromoform
0.6900 µg/L
No EPA limit set
worst single sample: 0.7000 µg/L
2/65 SYR4 2012–2019
Copper
39 µg/L 3%
of the EPA limit 1300 µg/L
worst single sample: 40 µg/L
2/11 SYR4 2012
Lead
2 µg/L 13%
of the EPA limit 15 µg/L
1/11 SYR4 2012
83 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalAsbestosAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitritePfbaPfdaPfdoaPfeesaPfhpaPfhpsPfmbaPfmpaPFNAPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Polychlorinated Biphenyls (PCB)ToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Susan Cutrell

Frequently asked questions about Parkland Light & Water Company

Is Parkland Light & Water Company tap water safe to drink?

EPA monitoring detected 21 contaminants in Parkland Light & Water Company's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Parkland Light & Water Company's water?

EPA monitoring detected Nitrate, TTHM, Chloroform, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.

How many people does Parkland Light & Water Company serve?

Parkland Light & Water Company reports serving 33,775 people in Washington, per its EPA record.

Has Parkland Light & Water Company had any water quality violations?

The EPA has 76 violations on file for Parkland Light & Water Company, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.