← Washington

Tap water quality report

Kelley Crest

EPA monitoring tested this supplier for 70 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

70
contaminants tested
5
detected
45
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Cowlitz

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
4,062
violations on file
1
still open
ViolationTypeStatusPeriod
TT Health-based Unaddressed 2021-03-10
MCL Health-based Resolved 2012-04-01 → 2012-04-30
MCL Health-based Resolved 2012-04-01 → 2012-04-30
MCL Health-based Resolved 2012-04-01 → 2012-04-30
MCL Health-based Archived 2006-12-01 → 2006-12-31
MCL Health-based Archived 1998-12-01 → 1998-12-31
MCL Health-based Archived 1998-12-01 → 1998-12-31
MCL Health-based Archived 1998-12-01 → 1998-12-31
MON Monitoring Resolved 2023-09-01 → 2023-09-30
Other Monitoring Resolved 2014-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
4300 µg/L 43%
of the EPA limit 10000 µg/L
20/22 SYR4 2012–2019
Lead
0.0040 mg/L 27%
of the EPA limit 0.0150 mg/L
8/8 LCR 2014
Lead
7.75 µg/L 52%
of the EPA limit 15 µg/L
worst single sample: 8 µg/L
2/2 SYR4 2012
Copper
54 µg/L 4.2%
of the EPA limit 1300 µg/L
1/2 SYR4 2012
Nitrate-Nitrite
4130 µg/L 41%
of the EPA limit 10000 µg/L
1/1 SYR4 2012
65 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDibromochloromethaneDichloroacetic AcidDinosebEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitritePentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Justin Hartmann

Frequently asked questions about Kelley Crest

Is Kelley Crest tap water safe to drink?

EPA monitoring detected 5 contaminants in Kelley Crest's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Kelley Crest's water?

EPA monitoring detected Nitrate, Lead, Lead, Copper, Nitrate-Nitrite. The full list with the level and data source for each is above.

How many people does Kelley Crest serve?

Kelley Crest reports serving 45 people in Washington, per its EPA record.

Has Kelley Crest had any water quality violations?

The EPA has 4062 violations on file for Kelley Crest, of which 8 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.