← Washington

Tap water quality report

Grays Harbor Co Water Dist 2

EPA monitoring tested this supplier for 79 contaminants and detected 8. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

79
contaminants tested
8
detected
5,112
people served
9
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Grays Harbor

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

9
health-based violations
73
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 1995-07-01 → 1995-07-31
MCL Health-based Archived 1995-07-01 → 1995-07-31
MCL Health-based Archived 1994-04-01 → 1994-04-30
MCL Health-based Archived 1993-08-01 → 1993-08-31
MCL Health-based Archived 1993-06-01 → 1993-06-30
MCL Health-based Archived 1992-07-01 → 1992-07-31
MCL Health-based Archived 1992-07-01 → 1992-07-31
MCL Health-based Archived 1992-07-01 → 1992-07-31
MCL Health-based Archived 1992-06-01 → 1992-06-30
Other Monitoring Resolved 2023-07-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0064 mg/L 43%
of the EPA limit 0.0150 mg/L
13/13 LCR 2025
TTHM
1.05 µg/L 1.3%
of the EPA limit 80 µg/L
worst single sample: 1.22 µg/L
5/5 SYR4 2012–2019
Chloroform
0.3670 µg/L
No EPA limit set
worst single sample: 0.3700 µg/L
4/10 SYR4 2012–2019
Bromodichloromethane
0.5500 µg/L
No EPA limit set
1/10 SYR4 2012–2019
Copper
310 µg/L 24%
of the EPA limit 1300 µg/L
1/1 SYR4 2017
Dibromochloromethane
0.6700 µg/L
No EPA limit set
1/10 SYR4 2012–2019
Lead
13 µg/L 87%
of the EPA limit 15 µg/L
1/1 SYR4 2017
Mercury
1 µg/L 50%
of the EPA limit 2 µg/L
1/1 SYR4 2017
71 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBariumBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumDichloromethaneDibromoacetic AcidDichloroacetic AcidEthylbenzeneFluorideHfpo-DaMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitrateNitrate-NitriteNitritePfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Trichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
John Millan

Frequently asked questions about Grays Harbor Co Water Dist 2

Is Grays Harbor Co Water Dist 2 tap water safe to drink?

EPA monitoring detected 8 contaminants in Grays Harbor Co Water Dist 2's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Grays Harbor Co Water Dist 2's water?

EPA monitoring detected Lead, TTHM, Chloroform, Bromodichloromethane, Copper, and others. The full list with the level and data source for each is above.

How many people does Grays Harbor Co Water Dist 2 serve?

Grays Harbor Co Water Dist 2 reports serving 5,112 people in Washington, per its EPA record.

Has Grays Harbor Co Water Dist 2 had any water quality violations?

The EPA has 73 violations on file for Grays Harbor Co Water Dist 2, of which 9 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.