← Washington

Tap water quality report

Cedar Glen Mobile Home Park

EPA monitoring tested this supplier for 71 contaminants and detected 13. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

71
contaminants tested
13
detected
284
people served
8
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Kitsap

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
19
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2020-09-30 → 2020-12-31
MCL Health-based Archived 2005-10-01 → 2005-10-31
MCL Health-based Archived 1997-12-01 → 1997-12-31
MCL Health-based Archived 1997-12-01 → 1997-12-31
MCL Health-based Archived 1997-12-01 → 1997-12-31
MCL Health-based Archived 1992-08-01 → 1992-08-31
MCL Health-based Archived 1992-08-01 → 1992-08-31
MCL Health-based Archived 1992-08-01 → 1992-08-31
MR Monitoring Archived 1999-09-01 → 1999-09-30
MR Monitoring Archived 1998-01-01 → 1998-01-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
1200 µg/L 12%
of the EPA limit 10000 µg/L
22/26 SYR4 2012–2018
Lead
0.00070 mg/L 4.7%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
Bromodichloromethane
0.7910 µg/L
No EPA limit set
worst single sample: 0.8000 µg/L
3/3 SYR4 2013–2017
Dibromochloromethane
0.9630 µg/L
No EPA limit set
worst single sample: 1 µg/L
3/3 SYR4 2013–2017
TTHM
2.257 µg/L 2.8%
of the EPA limit 80 µg/L
worst single sample: 2.27 µg/L
3/3 SYR4 2013–2017
Arsenic
4.95 µg/L 50%
of the EPA limit 10 µg/L
worst single sample: 5 µg/L
2/2 SYR4 2017
Barium
19.25 µg/L 1%
of the EPA limit 2000 µg/L
worst single sample: 20 µg/L
2/2 SYR4 2017
Copper
6.7 µg/L 0.5%
of the EPA limit 1300 µg/L
worst single sample: 7 µg/L
2/2 SYR4 2017
Chloroform
0.8395 µg/L
No EPA limit set
worst single sample: 0.8400 µg/L
2/5 SYR4 2013–2017
Chromium
4.8 µg/L 4.8%
of the EPA limit 100 µg/L
worst single sample: 5 µg/L
2/2 SYR4 2017
Lead
8.6 µg/L 57%
of the EPA limit 15 µg/L
worst single sample: 9 µg/L
2/2 SYR4 2017
Nitrate-Nitrite
1200 µg/L 12%
of the EPA limit 10000 µg/L
1/2 SYR4 2017
Selenium
1 µg/L 2%
of the EPA limit 50 µg/L
1/2 SYR4 2017
58 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChlordaneDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitritePentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)Total Polychlorinated Biphenyls (PCB)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
Kevin Odegard

Frequently asked questions about Cedar Glen Mobile Home Park

Is Cedar Glen Mobile Home Park tap water safe to drink?

EPA monitoring detected 13 contaminants in Cedar Glen Mobile Home Park's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cedar Glen Mobile Home Park's water?

EPA monitoring detected Nitrate, Lead, Bromodichloromethane, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.

How many people does Cedar Glen Mobile Home Park serve?

Cedar Glen Mobile Home Park reports serving 284 people in Washington, per its EPA record.

Has Cedar Glen Mobile Home Park had any water quality violations?

The EPA has 19 violations on file for Cedar Glen Mobile Home Park, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.