← Vermont

Tap water quality report

Killington Gateway I Condo Association

EPA monitoring tested this supplier for 67 contaminants and detected 6. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

67
contaminants tested
6
detected
68
people served
72
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Rutland

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

72
health-based violations
217
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-12-22
TT Health-based Resolved 2024-12-22
TT Health-based Resolved 2024-12-22
TT Health-based Resolved 2024-12-22
TT Health-based Resolved 2022-10-12
TT Health-based Resolved 2022-10-12
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30
MCL Health-based Resolved 2019-04-01 → 2019-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Combined Radium (-226 And -228)
7.7975 pCi/L 156%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 8.01 pCi/L
18/18 SYR4 2012–2019
Lead
0.1180 mg/L 787%
above the EPA limit of 0.0150 mg/L
16/16 LCR 2026
Copper
85.3 µg/L 6.6%
of the EPA limit 1300 µg/L
worst single sample: 91 µg/L
7/15 SYR4 2013–2019
Lead
1.595 µg/L 11%
of the EPA limit 15 µg/L
worst single sample: 1.6 µg/L
2/15 SYR4 2013–2019
Barium
31 µg/L 1.6%
of the EPA limit 2000 µg/L
1/1 SYR4 2013
Fluoride
530 µg/L 13%
of the EPA limit 4000 µg/L
1/1 SYR4 2013
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChloroformChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromochloromethaneDinosebEthylene DibromideEndrinEthylbenzeneHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitrateNitrate-NitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ROCK JR, THOMAS E
Phone
802-770-4022
Email
[email protected]

Frequently asked questions about Killington Gateway I Condo Association

Is Killington Gateway I Condo Association tap water safe to drink?

EPA monitoring detected 6 contaminants in Killington Gateway I Condo Association's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Killington Gateway I Condo Association's water?

EPA monitoring detected Combined Radium (-226 And -228), Lead, Copper, Lead, Barium, and others. The full list with the level and data source for each is above.

How many people does Killington Gateway I Condo Association serve?

Killington Gateway I Condo Association reports serving 68 people in Vermont, per its EPA record.

Has Killington Gateway I Condo Association had any water quality violations?

The EPA has 217 violations on file for Killington Gateway I Condo Association, of which 72 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.