← Vermont

Tap water quality report

Country Club Condominium

EPA monitoring tested this supplier for 74 contaminants and detected 15. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

74
contaminants tested
15
detected
80
people served
100
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Chittenden

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

100
health-based violations
449
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2018-10-01 → 2018-12-31
MCL Health-based Resolved 2018-10-01 → 2018-12-31
MCL Health-based Resolved 2018-10-01 → 2018-12-31
MCL Health-based Resolved 2018-10-01 → 2018-12-31
MCL Health-based Resolved 2018-10-01 → 2018-12-31
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30
MCL Health-based Resolved 2018-04-01 → 2018-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
105 µg/L 8.1%
of the EPA limit 1300 µg/L
worst single sample: 260 µg/L
76/80 SYR4 2012–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
56/56 LCR 2026
Combined Radium (-226 And -228)
6.258 pCi/L 125%
of the EPA limit, at the 95th percentile of samples — 5 pCi/L
worst single sample: 8.84 pCi/L
37/37 SYR4 2012–2019
Lead
15.44 µg/L 103%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 97 µg/L
37/80 SYR4 2012–2019
Nitrate
1100 µg/L 11%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
1.895 µg/L
No EPA limit set
worst single sample: 2 µg/L
8/8 SYR4 2012–2018
Chloroform
6.515 µg/L
No EPA limit set
worst single sample: 6.9 µg/L
8/8 SYR4 2012–2018
TTHM
8.36 µg/L 10%
of the EPA limit 80 µg/L
worst single sample: 8.6 µg/L
5/5 SYR4 2012–2017
Combined Uranium
4.302 µg/L 14%
of the EPA limit 30 µg/L
worst single sample: 4.34 µg/L
3/3 SYR4 2014–2019
Dichloroacetic Acid
6.955 µg/L
No EPA limit set
worst single sample: 7.1 µg/L
2/5 SYR4 2012–2017
Total Haloacetic Acids (HAA5)
10.185 µg/L 17%
of the EPA limit 60 µg/L
worst single sample: 10.5 µg/L
2/5 SYR4 2012–2017
Barium
24 µg/L 1.2%
of the EPA limit 2000 µg/L
1/1 SYR4 2013
Dibromochloromethane
0.7000 µg/L
No EPA limit set
1/8 SYR4 2012–2018
Gross Alpha, Excl. Radon And U
10.39 pCi/L 69%
of the EPA limit 15 pCi/L
1/1 SYR4 2019
Trichloroacetic Acid
3.4 µg/L
No EPA limit set
1/5 SYR4 2012–2017
59 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalBromoformChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BRADLEY, PATRICK
Phone
802-863-6940
Email
[email protected]

Frequently asked questions about Country Club Condominium

Is Country Club Condominium tap water safe to drink?

EPA monitoring detected 15 contaminants in Country Club Condominium's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Country Club Condominium's water?

EPA monitoring detected Copper, Lead, Combined Radium (-226 And -228), Lead, Nitrate, and others. The full list with the level and data source for each is above.

How many people does Country Club Condominium serve?

Country Club Condominium reports serving 80 people in Vermont, per its EPA record.

Has Country Club Condominium had any water quality violations?

The EPA has 449 violations on file for Country Club Condominium, of which 100 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.