EPA monitoring tested this supplier for 66 contaminants and detected 10. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

66
contaminants tested
10
detected
252
people served
47
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Windsor

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

47
health-based violations
645
violations on file
12
still open
ViolationTypeStatusPeriod
TT Health-based Addressed 2024-10-17
TT Health-based Addressed 2024-10-17
TT Health-based Addressed 2024-10-17
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2014-11-01 → 2014-11-30
MCL Health-based Resolved 2013-10-01 → 2013-10-31

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
0.0019 mg/L 13%
of the EPA limit 0.0150 mg/L
27/27 LCR 2026
Copper
626 µg/L 48%
of the EPA limit 1300 µg/L
worst single sample: 870 µg/L
25/25 SYR4 2013–2018
Lead
15.265 µg/L 102%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 19.4 µg/L
24/25 SYR4 2013–2018
Nitrate
780 µg/L 7.8%
of the EPA limit 10000 µg/L
14/16 SYR4 2012–2019
Bromodichloromethane
1.08 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
3/10 SYR4 2012–2017
Dibromochloromethane
1.09 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
3/10 SYR4 2012–2017
Chloroform
1.08 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
2/10 SYR4 2012–2017
Bromoform
0.9000 µg/L
No EPA limit set
1/10 SYR4 2012–2017
Chlorobenzene
0.5000 µg/L 0.5%
of the EPA limit 100 µg/L
1/10 SYR4 2012–2017
Combined Radium (-226 And -228)
0.4360 pCi/L 8.7%
of the EPA limit 5 pCi/L
1/1 SYR4 2014
56 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAtrazineBhc-GammaBariumBenzeneBenzo(A)PyreneBeryllium, TotalCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneFluorideHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
NIELSEN, JAMES M
Phone
802-672-5067
Email
[email protected]

Frequently asked questions about Ledges System 1

Is Ledges System 1 tap water safe to drink?

EPA monitoring detected 10 contaminants in Ledges System 1's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Ledges System 1's water?

EPA monitoring detected Lead, Copper, Lead, Nitrate, Bromodichloromethane, and others. The full list with the level and data source for each is above.

How many people does Ledges System 1 serve?

Ledges System 1 reports serving 252 people in Vermont, per its EPA record.