← Vermont

Tap water quality report

Suntec Forest Condominium

EPA monitoring tested this supplier for 41 contaminants and detected 5. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

41
contaminants tested
5
detected
240
people served
28
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Windham

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

28
health-based violations
43
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2024-01-01 → 2024-06-30
TT Health-based Resolved 2024-01-01 → 2024-06-30
TT Health-based Resolved 2024-01-01 → 2024-06-30
TT Health-based Resolved 2024-01-01 → 2024-06-30
TT Health-based Resolved 2019-07-29
TT Health-based Resolved 2019-07-29
TT Health-based Resolved 2019-07-29
TT Health-based Resolved 2017-10-28
TT Health-based Resolved 2017-10-28
TT Health-based Resolved 2017-10-28

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Lead
73 µg/L 487%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 1100 µg/L
101/101 SYR4 2012–2019
Copper
441.5 µg/L 34%
of the EPA limit 1300 µg/L
worst single sample: 1090 µg/L
100/101 SYR4 2012–2019
Lead
0.0035 mg/L 23%
of the EPA limit 0.0150 mg/L
34/34 LCR 2025
Nitrate
980 µg/L 9.8%
of the EPA limit 10000 µg/L
4/16 SYR4 2012–2019
Fluoride
130 µg/L 3.3%
of the EPA limit 4000 µg/L
1/1 SYR4 2014
36 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-DichloropropaneAntimony, TotalArsenicBariumBenzeneBeryllium, TotalBromodichloromethaneBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChloroformChromiumCombined Radium (-226 And -228)DichloromethaneDibromochloromethaneEthylbenzeneMercurySeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
BOEREM, DWIGHT
Phone
802-473-3121
Email
[email protected]

Frequently asked questions about Suntec Forest Condominium

Is Suntec Forest Condominium tap water safe to drink?

EPA monitoring detected 5 contaminants in Suntec Forest Condominium's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Suntec Forest Condominium's water?

EPA monitoring detected Lead, Copper, Lead, Nitrate, Fluoride. The full list with the level and data source for each is above.

How many people does Suntec Forest Condominium serve?

Suntec Forest Condominium reports serving 240 people in Vermont, per its EPA record.

Has Suntec Forest Condominium had any water quality violations?

The EPA has 43 violations on file for Suntec Forest Condominium, of which 28 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.