← Vermont

Tap water quality report

Northfield Water Dept

EPA monitoring tested this supplier for 80 contaminants and detected 12. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

80
contaminants tested
12
detected
5,145
people served
20
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Washington

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

20
health-based violations
39
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Archived 2000-09-01 → 2000-09-30
MCL Health-based Resolved 2000-09-01 → 2000-09-30
MCL Health-based Resolved 2000-09-01 → 2000-09-30
MCL Health-based Resolved 2000-09-01 → 2000-09-30
MCL Health-based Resolved 2000-09-01 → 2000-09-30
MCL Health-based Resolved 2000-09-01 → 2000-09-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30
MCL Health-based Resolved 2000-06-01 → 2000-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Fluoride
1000 µg/L 25%
of the EPA limit 4000 µg/L
worst single sample: 1900 µg/L
334/344 SYR4 2012–2019
Copper
292 µg/L 22%
of the EPA limit 1300 µg/L
worst single sample: 620 µg/L
53/60 SYR4 2013–2019
Lead
18.62 µg/L 124%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 37 µg/L
40/60 SYR4 2013–2019
Lead
0.0050 mg/L 33%
of the EPA limit 0.0150 mg/L
18/18 LCR 2025
Nitrate
800 µg/L 8%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
2.6 µg/L
No EPA limit set
7/9 SYR4 2012–2019
Chloroform
7.5 µg/L
No EPA limit set
worst single sample: 8.1 µg/L
7/9 SYR4 2012–2019
TTHM
11.32 µg/L 14%
of the EPA limit 80 µg/L
worst single sample: 11.8 µg/L
7/7 SYR4 2012–2019
Dibromochloromethane
1.5 µg/L
No EPA limit set
6/9 SYR4 2012–2019
Dichloroacetic Acid
4.29 µg/L
No EPA limit set
worst single sample: 4.3 µg/L
3/7 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
4.295 µg/L 7.2%
of the EPA limit 60 µg/L
worst single sample: 4.3 µg/L
2/7 SYR4 2012–2019
Combined Radium (-226 And -228)
0.5640 pCi/L 11%
of the EPA limit 5 pCi/L
1/1 SYR4 2013
68 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicBariumBenzeneBeryllium, TotalBromoformChlorobenzeneCyanideCadmiumCarbon TetrachlorideChromiumCombined UraniumDichloromethaneDibromoacetic AcidEthylbenzeneGross Alpha, Excl. Radon And UHfpo-DaMercuryMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaSeleniumStyreneTetrachloroethyleneThallium, TotalTolueneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
RUSSO, JAMES L
Phone
802-279-1274
Email
[email protected]

Frequently asked questions about Northfield Water Dept

Is Northfield Water Dept tap water safe to drink?

EPA monitoring detected 12 contaminants in Northfield Water Dept's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Northfield Water Dept's water?

EPA monitoring detected Fluoride, Copper, Lead, Lead, Nitrate, and others. The full list with the level and data source for each is above.

How many people does Northfield Water Dept serve?

Northfield Water Dept reports serving 5,145 people in Vermont, per its EPA record.

Has Northfield Water Dept had any water quality violations?

The EPA has 39 violations on file for Northfield Water Dept, of which 20 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.