Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2015-06-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-06-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-06-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-06-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-06-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2015-06-01 → 2015-06-30 |
| MCL | Health-based | Resolved | 2013-07-01 → 2013-07-31 |
| MCL | Health-based | Resolved | 2013-07-01 → 2013-07-31 |
| MCL | Health-based | Resolved | 2013-07-01 → 2013-07-31 |
| MCL | Health-based | Resolved | 2013-06-01 → 2013-06-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 3975 µg/L 40% of the EPA limit 10000 µg/L
worst single sample: 4100 µg/L | 26/28 | SYR4 | 2013–2019 |
| Lead | 0.0024 mg/L 16% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2025 |
| Copper | 109 µg/L 8.4% of the EPA limit 1300 µg/L
worst single sample: 160 µg/L | 18/25 | SYR4 | 2015–2019 |
| Lead | 60.66 µg/L 404% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 89.3 µg/L | 9/25 | SYR4 | 2015–2019 |
| Bromoform | 0.7000 µg/L No EPA limit set | 3/9 | SYR4 | 2012–2018 |
| Dibromochloromethane | 0.8000 µg/L No EPA limit set | 3/9 | SYR4 | 2012–2018 |
| Chloroform | 1.555 µg/L No EPA limit set
worst single sample: 1.6 µg/L | 2/9 | SYR4 | 2012–2018 |
| TTHM | 1.5 µg/L 1.9% of the EPA limit 80 µg/L | 2/3 | SYR4 | 2012–2018 |
| Barium | 32 µg/L 1.6% of the EPA limit 2000 µg/L | 1/2 | SYR4 | 2014 |
| Bromodichloromethane | 0.9000 µg/L No EPA limit set | 1/9 | SYR4 | 2012–2018 |
| Dibromoacetic Acid | 1.1 µg/L No EPA limit set | 1/3 | SYR4 | 2012–2018 |
| Nitrate-Nitrite | 4300 µg/L 43% of the EPA limit 10000 µg/L | 1/2 | SYR4 | 2012 |
| Total Haloacetic Acids (HAA5) | 1.1 µg/L 1.8% of the EPA limit 60 µg/L | 1/3 | SYR4 | 2012–2018 |
60 contaminants tested, none detected
Utility contact
Frequently asked questions about Fort Warren Mhp
Is Fort Warren Mhp tap water safe to drink?
EPA monitoring detected 13 contaminants in Fort Warren Mhp's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Fort Warren Mhp's water?
EPA monitoring detected Nitrate, Lead, Copper, Lead, Bromoform, and others. The full list with the level and data source for each is above.
How many people does Fort Warren Mhp serve?
Fort Warren Mhp reports serving 129 people in Vermont, per its EPA record.
Has Fort Warren Mhp had any water quality violations?
The EPA has 72 violations on file for Fort Warren Mhp, of which 21 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.