Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| Other | Monitoring | Resolved | 2022-07-01 |
| Other | Monitoring | Resolved | 2022-07-01 |
| Other | Monitoring | Resolved | 2022-07-01 |
| MR | Monitoring | Resolved | 2019-12-30 |
| MR | Monitoring | Resolved | 2019-12-30 |
| MR | Monitoring | Resolved | 2019-12-30 |
| Other | Monitoring | Resolved | 2018-07-01 |
| Other | Monitoring | Resolved | 2018-07-01 |
| MR | Monitoring | Resolved | 2017-09-01 → 2017-09-30 |
| MR | Monitoring | Resolved | 2017-09-01 → 2017-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1070.07 µg/L 82% of the EPA limit 1300 µg/L
worst single sample: 1761.34 µg/L | 122/122 | SYR4 | 2018–2019 |
| TTHM | 10.81 µg/L 14% of the EPA limit 80 µg/L
worst single sample: 13.8 µg/L | 14/28 | SYR4 | 2018–2019 |
| Lead | 3.46105 µg/L 23% of the EPA limit 15 µg/L
worst single sample: 4.599 µg/L | 12/122 | SYR4 | 2018–2019 |
| Bromodichloromethane | 2.9 µg/L No EPA limit set
worst single sample: 3.3 µg/L | 9/24 | SYR4 | 2018–2019 |
| Dibromochloromethane | 1.54 µg/L No EPA limit set
worst single sample: 1.7 µg/L | 9/24 | SYR4 | 2018–2019 |
| Chloroform | 7.715 µg/L No EPA limit set
worst single sample: 8.8 µg/L | 8/24 | SYR4 | 2018–2019 |
| Dichloroacetic Acid | 6.275 µg/L No EPA limit set
worst single sample: 6.6 µg/L | 6/24 | SYR4 | 2018–2019 |
| Total Haloacetic Acids (HAA5) | 15.62 µg/L 26% of the EPA limit 60 µg/L
worst single sample: 16.8 µg/L | 5/28 | SYR4 | 2018–2019 |
| Lead | 0.00069 mg/L 4.6% of the EPA limit 0.0150 mg/L | 4/4 | LCR | 2024 |
| Trichloroacetic Acid | 4.15 µg/L No EPA limit set
worst single sample: 4.3 µg/L | 4/24 | SYR4 | 2018–2019 |
| Bromoform | 0.6000 µg/L No EPA limit set | 2/24 | SYR4 | 2018–2019 |
33 contaminants tested, none detected
Utility contact
Frequently asked questions about Boyer Hill Military Housing
Is Boyer Hill Military Housing tap water safe to drink?
EPA monitoring detected 11 contaminants in Boyer Hill Military Housing's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Boyer Hill Military Housing's water?
EPA monitoring detected Copper, TTHM, Lead, Bromodichloromethane, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Boyer Hill Military Housing serve?
Boyer Hill Military Housing reports serving 3,300 people in Utah, per its EPA record.
Has Boyer Hill Military Housing had any water quality violations?
The EPA has 17 violations on file for Boyer Hill Military Housing, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.