← Texas

Tap water quality report

Lakeway Mud

EPA monitoring tested this supplier for 108 contaminants and detected 20. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

108
contaminants tested
20
detected
10,512
people served
0
health-based violations
Water source
Surface water
Ownership
Local government
Counties served
Travis

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
3
violations on file
0
still open
ViolationTypeStatusPeriod
MR Monitoring Resolved 2013-12-30
MR Monitoring Resolved 2003-10-01 → 2003-10-31
MR Monitoring Resolved 1992-07-01 → 1993-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
603 µg/L 46%
of the EPA limit 1300 µg/L
worst single sample: 1600 µg/L
115/115 SYR4 2013–2019
Bromodichloromethane
21.22 µg/L
No EPA limit set
worst single sample: 36.5 µg/L
110/110 SYR4 2012–2019
Chloroform
39.695 µg/L
No EPA limit set
worst single sample: 46.1 µg/L
110/110 SYR4 2012–2019
Dibromochloromethane
14.3 µg/L
No EPA limit set
worst single sample: 28.6 µg/L
109/110 SYR4 2012–2019
Dichloroacetic Acid
20.95 µg/L
No EPA limit set
worst single sample: 34.4 µg/L
102/102 SYR4 2012–2019
TTHM
70.08 µg/L 88%
of the EPA limit 80 µg/L
worst single sample: 109 µg/L
102/103 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
34.045 µg/L 57%
of the EPA limit 60 µg/L
worst single sample: 53.4 µg/L
102/102 SYR4 2012–2019
Trichloroacetic Acid
12.5 µg/L
No EPA limit set
worst single sample: 15.1 µg/L
101/102 SYR4 2012–2019
Dibromoacetic Acid
5.3 µg/L
No EPA limit set
worst single sample: 5.9 µg/L
99/102 SYR4 2012–2019
Bromoform
5.2 µg/L
No EPA limit set
worst single sample: 11.5 µg/L
92/110 SYR4 2012–2019
Lead
5.655 µg/L 38%
of the EPA limit 15 µg/L
worst single sample: 16 µg/L
58/115 SYR4 2013–2019
Nitrate
550 µg/L 5.5%
of the EPA limit 10000 µg/L
18/18 SYR4 2012–2019
Lead
0.0033 mg/L 22%
of the EPA limit 0.0150 mg/L
13/13 LCR 2023
Fluoride
643 µg/L 16%
of the EPA limit 4000 µg/L
worst single sample: 650 µg/L
8/8 SYR4 2012–2019
Monochloroacetic Acid
3.555 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
8/102 SYR4 2012–2019
Barium
64.67 µg/L 3.2%
of the EPA limit 2000 µg/L
worst single sample: 64.7 µg/L
7/7 SYR4 2013–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
3/3 SYR4 2013–2019
Antimony, Total
0.2540 µg/L 4.2%
of the EPA limit 6 µg/L
1/7 SYR4 2013–2019
Cyanide
110 µg/L 55%
of the EPA limit 200 µg/L
1/6 SYR4 2014–2019
Chromium
1.7 µg/L 1.7%
of the EPA limit 100 µg/L
1/7 SYR4 2013–2019
88 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CHRISTIAN, LAWRENCE, M
Phone
512-261-6681
Email
[email protected]

Frequently asked questions about Lakeway Mud

Is Lakeway Mud tap water safe to drink?

EPA monitoring detected 20 contaminants in Lakeway Mud's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lakeway Mud's water?

EPA monitoring detected Copper, Bromodichloromethane, Chloroform, Dibromochloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Lakeway Mud serve?

Lakeway Mud reports serving 10,512 people in Texas, per its EPA record.

Has Lakeway Mud had any water quality violations?

The EPA has 3 violations on file for Lakeway Mud, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.