Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Unaddressed | 2026-04-01 |
| TT | Health-based | Unaddressed | 2026-04-01 |
| TT | Health-based | Unaddressed | 2026-04-01 |
| TT | Health-based | Unaddressed | 2026-03-31 |
| TT | Health-based | Unaddressed | 2026-03-31 |
| TT | Health-based | Unaddressed | 2026-03-31 |
| TT | Health-based | Unaddressed | 2025-12-01 |
| TT | Health-based | Unaddressed | 2025-12-01 |
| TT | Health-based | Unaddressed | 2025-12-01 |
| MCL | Health-based | Resolved | 2024-07-01 → 2024-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Bromodichloromethane | 26.625 µg/L No EPA limit set
worst single sample: 26.8 µg/L | 24/24 | SYR4 | 2012–2019 |
| Chloroform | 68.045 µg/L No EPA limit set
worst single sample: 74.3 µg/L | 24/24 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 29.025 µg/L No EPA limit set
worst single sample: 30.6 µg/L | 24/24 | SYR4 | 2012–2019 |
| TTHM | 94.39 µg/L 118% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 107 µg/L | 24/24 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 52.96 µg/L 88% of the EPA limit 60 µg/L
worst single sample: 56.1 µg/L | 24/24 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 24.785 µg/L No EPA limit set
worst single sample: 26.3 µg/L | 22/24 | SYR4 | 2012–2019 |
| Copper | 641.7 µg/L 49% of the EPA limit 1300 µg/L
worst single sample: 823 µg/L | 15/15 | SYR4 | 2015–2018 |
| Dibromochloromethane | 13.76 µg/L No EPA limit set
worst single sample: 14.8 µg/L | 14/24 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 3.74 µg/L No EPA limit set
worst single sample: 3.9 µg/L | 9/24 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 3.78 µg/L No EPA limit set
worst single sample: 4.2 µg/L | 7/24 | SYR4 | 2012–2019 |
| Lead | 2.0125 µg/L 13% of the EPA limit 15 µg/L
worst single sample: 2.26 µg/L | 6/15 | SYR4 | 2015–2018 |
| Bromoform | 1.658 µg/L No EPA limit set
worst single sample: 1.69 µg/L | 5/24 | SYR4 | 2012–2019 |
| Monobromoacetic Acid | 2.66 µg/L No EPA limit set
worst single sample: 2.8 µg/L | 5/24 | SYR4 | 2012–2019 |
| Lead | 0.0280 mg/L 187% above the EPA limit of 0.0150 mg/L | 2/2 | LCR | 2025 |
Utility contact
Frequently asked questions about Country Lakes Water Supply
Is Country Lakes Water Supply tap water safe to drink?
EPA monitoring detected 14 contaminants in Country Lakes Water Supply's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Country Lakes Water Supply's water?
EPA monitoring detected Bromodichloromethane, Chloroform, Dichloroacetic Acid, TTHM, Total Haloacetic Acids (HAA5), and others. The full list with the level and data source for each is above.
How many people does Country Lakes Water Supply serve?
Country Lakes Water Supply reports serving 144 people in Texas, per its EPA record.
Has Country Lakes Water Supply had any water quality violations?
The EPA has 319 violations on file for Country Lakes Water Supply, of which 19 are health-based (a contaminant limit or required treatment was breached) and 19 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.