← Texas

Tap water quality report

Lakeland Services

EPA monitoring tested this supplier for 14 contaminants and detected 11. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

14
contaminants tested
11
detected
63
people served
438
health-based violations
Water source
GWP
Ownership
Private
Counties served
McCulloch

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

438
health-based violations
479
violations on file
4
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-10-01 → 2024-12-31
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30
MCL Health-based Resolved 2024-07-01 → 2024-09-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
106 µg/L 8.2%
of the EPA limit 1300 µg/L
worst single sample: 160 µg/L
19/30 SYR4 2014–2019
Lead
512.05 µg/L 3414%
of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 1100 µg/L
12/30 SYR4 2014–2019
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
7/7 LCR 2025
Bromodichloromethane
5.325 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
6/6 SYR4 2012–2018
Bromoform
5.775 µg/L
No EPA limit set
worst single sample: 6.5 µg/L
6/6 SYR4 2012–2018
Dibromochloromethane
8.075 µg/L
No EPA limit set
worst single sample: 8.6 µg/L
6/6 SYR4 2012–2018
Chloroform
3.62 µg/L
No EPA limit set
worst single sample: 3.7 µg/L
5/6 SYR4 2012–2018
TTHM
23 µg/L 29%
of the EPA limit 80 µg/L
worst single sample: 24.4 µg/L
5/5 SYR4 2014–2018
Dibromoacetic Acid
1.4 µg/L
No EPA limit set
4/5 SYR4 2014–2018
Dichloroacetic Acid
3.755 µg/L
No EPA limit set
worst single sample: 3.8 µg/L
4/5 SYR4 2014–2018
Total Haloacetic Acids (HAA5)
5.155 µg/L 8.6%
of the EPA limit 60 µg/L
worst single sample: 5.2 µg/L
4/5 SYR4 2014–2018
3 contaminants tested, none detected
Monobromoacetic AcidMonochloroacetic AcidTrichloroacetic Acid

Utility contact

Contact
DOBSON, DEBORAH
Phone
325-240-0121
Email
[email protected]

Frequently asked questions about Lakeland Services

Is Lakeland Services tap water safe to drink?

EPA monitoring detected 11 contaminants in Lakeland Services's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Lakeland Services's water?

EPA monitoring detected Copper, Lead, Lead, Bromodichloromethane, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Lakeland Services serve?

Lakeland Services reports serving 63 people in Texas, per its EPA record.

Has Lakeland Services had any water quality violations?

The EPA has 479 violations on file for Lakeland Services, of which 438 are health-based (a contaminant limit or required treatment was breached) and 4 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.