Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-04-01 → 2017-06-30 |
| MCL | Health-based | Resolved | 2017-01-01 → 2017-03-31 |
| MCL | Health-based | Resolved | 2017-01-01 → 2017-03-31 |
| MCL | Health-based | Resolved | 2017-01-01 → 2017-03-31 |
| MCL | Health-based | Resolved | 2017-01-01 → 2017-03-31 |
| MCL | Health-based | Resolved | 2008-09-01 → 2008-09-30 |
| MCL | Health-based | Resolved | 2008-09-01 → 2008-09-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Chloroform | 12.055 µg/L No EPA limit set
worst single sample: 13.2 µg/L | 44/48 | SYR4 | 2012–2019 |
| TTHM | 105.3 µg/L 132% of the EPA limit, at the 95th percentile of samples — 80 µg/L
worst single sample: 125 µg/L | 35/37 | SYR4 | 2012–2019 |
| Bromodichloromethane | 26.87 µg/L No EPA limit set
worst single sample: 29.9 µg/L | 32/48 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 16.35 µg/L 27% of the EPA limit 60 µg/L
worst single sample: 17.8 µg/L | 31/37 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 4.16 µg/L No EPA limit set
worst single sample: 4.6 µg/L | 29/37 | SYR4 | 2012–2019 |
| Copper | 822.8 µg/L 63% of the EPA limit 1300 µg/L
worst single sample: 1380 µg/L | 28/33 | SYR4 | 2013–2017 |
| Lead | 16.14 µg/L 108% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 29.8 µg/L | 22/33 | SYR4 | 2013–2017 |
| Dibromochloromethane | 46.9 µg/L No EPA limit set
worst single sample: 57.3 µg/L | 21/48 | SYR4 | 2012–2019 |
| Nitrate | 30 µg/L 0.3% of the EPA limit 10000 µg/L | 18/32 | SYR4 | 2012–2019 |
| Bromoform | 22.02 µg/L No EPA limit set
worst single sample: 24.9 µg/L | 17/48 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 8.8 µg/L No EPA limit set
worst single sample: 9.6 µg/L | 17/37 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 4.225 µg/L No EPA limit set
worst single sample: 4.9 µg/L | 16/37 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 10/10 | LCR | 2024 |
| Barium | 55.865 µg/L 2.8% of the EPA limit 2000 µg/L
worst single sample: 56.9 µg/L | 4/4 | SYR4 | 2014–2019 |
| Fluoride | 728.5 µg/L 18% of the EPA limit 4000 µg/L
worst single sample: 730 µg/L | 4/4 | SYR4 | 2014–2017 |
| Nitrate-Nitrite | 20 µg/L 0.2% of the EPA limit 10000 µg/L | 4/6 | SYR4 | 2012–2015 |
| Monochloroacetic Acid | 6.13 µg/L No EPA limit set
worst single sample: 6.3 µg/L | 2/37 | SYR4 | 2012–2019 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 1/1 | SYR4 | 2015 |
61 contaminants tested, none detected
Utility contact
Frequently asked questions about Meeker Mwd
Is Meeker Mwd tap water safe to drink?
EPA monitoring detected 18 contaminants in Meeker Mwd's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Meeker Mwd's water?
EPA monitoring detected Chloroform, TTHM, Bromodichloromethane, Total Haloacetic Acids (HAA5), Dichloroacetic Acid, and others. The full list with the level and data source for each is above.
How many people does Meeker Mwd serve?
Meeker Mwd reports serving 4,071 people in Texas, per its EPA record.
Has Meeker Mwd had any water quality violations?
The EPA has 79 violations on file for Meeker Mwd, of which 57 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.