Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-04-01 → 2005-06-30 |
| MCL | Health-based | Resolved | 2005-01-01 → 2005-03-31 |
PFAS detected
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Nitrate | 897.5 µg/L 9% of the EPA limit 10000 µg/L
worst single sample: 4400 µg/L | 110/112 | SYR4 | 2012–2019 |
| Dibromochloromethane | 7.69 µg/L No EPA limit set
worst single sample: 12 µg/L | 92/97 | SYR4 | 2012–2019 |
| Bromoform | 5.2 µg/L No EPA limit set
worst single sample: 6.1 µg/L | 76/97 | SYR4 | 2012–2019 |
| Bromodichloromethane | 19.42 µg/L No EPA limit set
worst single sample: 36.8 µg/L | 75/97 | SYR4 | 2012–2019 |
| TTHM | 70.93 µg/L 89% of the EPA limit 80 µg/L
worst single sample: 132 µg/L | 64/64 | SYR4 | 2012–2019 |
| Chloroform | 39.225 µg/L No EPA limit set
worst single sample: 81.6 µg/L | 58/97 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 107.15 µg/L 179% of the EPA limit, at the 95th percentile of samples — 60 µg/L
worst single sample: 117 µg/L | 58/64 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 9.575 µg/L No EPA limit set
worst single sample: 11.9 µg/L | 56/64 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 67.7 µg/L No EPA limit set
worst single sample: 86.7 µg/L | 56/64 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 20.8 µg/L No EPA limit set
worst single sample: 24.7 µg/L | 54/64 | SYR4 | 2012–2019 |
| Copper | 98.1 µg/L 7.5% of the EPA limit 1300 µg/L
worst single sample: 110 µg/L | 44/48 | SYR4 | 2013–2017 |
| Monochloroacetic Acid | 9.5 µg/L No EPA limit set
worst single sample: 10.7 µg/L | 21/64 | SYR4 | 2012–2019 |
| Barium | 55 µg/L 2.8% of the EPA limit 2000 µg/L | 14/14 | SYR4 | 2013–2019 |
| Monobromoacetic Acid | 2.705 µg/L No EPA limit set
worst single sample: 2.9 µg/L | 14/64 | SYR4 | 2012–2019 |
| Nitrate-Nitrite | 900.5 µg/L 9% of the EPA limit 10000 µg/L
worst single sample: 920 µg/L | 14/15 | SYR4 | 2012–2015 |
| Fluoride | 534.5 µg/L 13% of the EPA limit 4000 µg/L
worst single sample: 540 µg/L | 12/12 | SYR4 | 2014–2019 |
| Lithium | 75.6 µg/L No EPA limit set | 12/16 | UCMR-5 | 2023 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 11/11 | LCR | 2023 |
| Combined Radium (-226 And -228) | 1.5 pCi/L 30% of the EPA limit 5 pCi/L | 9/9 | SYR4 | 2012–2018 |
| Chromium | 3.812 µg/L 3.8% of the EPA limit 100 µg/L
worst single sample: 4.76 µg/L | 7/14 | SYR4 | 2013–2019 |
| Xylenes, Total | 2 µg/L 0% of the EPA limit 10000 µg/L | 6/34 | SYR4 | 2013–2019 |
| Lead | 4.94 µg/L 33% of the EPA limit 15 µg/L
worst single sample: 5.2 µg/L | 5/48 | SYR4 | 2013–2017 |
| Dalapon | 2.54 µg/L 1.3% of the EPA limit 200 µg/L
worst single sample: 2.6 µg/L | 4/47 | SYR4 | 2012–2019 |
| Ethylbenzene | 0.5000 µg/L 0.1% of the EPA limit 700 µg/L | 1/34 | SYR4 | 2013–2019 |
| Nitrite | 20 µg/L 2% of the EPA limit 1000 µg/L | 1/16 | SYR4 | 2012–2015 |
| Selenium | 3.1 µg/L 6.2% of the EPA limit 50 µg/L | 1/14 | SYR4 | 2013–2019 |
80 contaminants tested, none detected
Utility contact
Frequently asked questions about Hill County Wsc
Is Hill County Wsc tap water safe to drink?
EPA monitoring detected 29 contaminants in Hill County Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Hill County Wsc's water?
EPA monitoring detected Nitrate, Dibromochloromethane, Bromoform, Bromodichloromethane, TTHM, and others. The full list with the level and data source for each is above.
How many people does Hill County Wsc serve?
Hill County Wsc reports serving 4,383 people in Texas, per its EPA record.
Has Hill County Wsc had any water quality violations?
The EPA has 43 violations on file for Hill County Wsc, of which 42 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.