← Texas

Tap water quality report

Cedar Creek Water

EPA monitoring tested this supplier for 109 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
18
detected
3,720
people served
0
health-based violations
Water source
Ground water
Ownership
Private
Counties served
Hill

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
5
violations on file
0
still open
ViolationTypeStatusPeriod
RPT Monitoring Resolved 2025-07-02
Other Monitoring Resolved 2014-07-01
Other Monitoring Resolved 2014-07-01
MR Monitoring Resolved 2013-12-30
MR Monitoring Resolved 1992-07-01 → 1993-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
122.105 µg/L 1.2%
of the EPA limit 10000 µg/L
worst single sample: 132 µg/L
64/64 SYR4 2012–2019
Copper
170 µg/L 13%
of the EPA limit 1300 µg/L
worst single sample: 240 µg/L
56/68 SYR4 2012–2019
Dibromochloromethane
12.135 µg/L
No EPA limit set
worst single sample: 20 µg/L
14/34 SYR4 2012–2019
Bromoform
11.028 µg/L
No EPA limit set
worst single sample: 16 µg/L
12/34 SYR4 2012–2019
Combined Radium (-226 And -228)
1.5 pCi/L 30%
of the EPA limit 5 pCi/L
12/12 SYR4 2012–2018
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
12/12 LCR 2025
Nitrate-Nitrite
60 µg/L 0.6%
of the EPA limit 10000 µg/L
12/12 SYR4 2012–2015
Bromodichloromethane
7.365 µg/L
No EPA limit set
worst single sample: 9.8 µg/L
11/34 SYR4 2012–2019
Barium
47.02 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 47.7 µg/L
9/9 SYR4 2012–2018
Fluoride
413.9 µg/L 10%
of the EPA limit 4000 µg/L
worst single sample: 416 µg/L
8/8 SYR4 2014–2017
Lithium
81.1 µg/L
No EPA limit set
8/8 UCMR-5 2023
Chloroform
3.553 µg/L
No EPA limit set
worst single sample: 3.79 µg/L
7/34 SYR4 2012–2019
Lead
8.925 µg/L 60%
of the EPA limit 15 µg/L
worst single sample: 9.9 µg/L
6/68 SYR4 2012–2019
TTHM
16.788 µg/L 21%
of the EPA limit 80 µg/L
worst single sample: 18.7 µg/L
5/11 SYR4 2013–2019
Chromium
1.525 µg/L 1.5%
of the EPA limit 100 µg/L
worst single sample: 1.6 µg/L
4/9 SYR4 2012–2018
Ethylbenzene
0.6220 µg/L 0.1%
of the EPA limit 700 µg/L
1/23 SYR4 2012–2019
Selenium
5.3 µg/L 11%
of the EPA limit 50 µg/L
1/9 SYR4 2012–2018
Xylenes, Total
3.2 µg/L 0%
of the EPA limit 10000 µg/L
1/23 SYR4 2012–2019
91 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDibromoacetic AcidDichloroacetic AcidDinosebEthylene DibromideEndrinGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSimazineStyreneTetrachloroethyleneThallium, TotalTolueneTotal Haloacetic Acids (HAA5)ToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
CHEEK, THOMAS
Phone
254-687-2331
Email
[email protected]

Frequently asked questions about Cedar Creek Water

Is Cedar Creek Water tap water safe to drink?

EPA monitoring detected 18 contaminants in Cedar Creek Water's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Cedar Creek Water's water?

EPA monitoring detected Nitrate, Copper, Dibromochloromethane, Bromoform, Combined Radium (-226 And -228), and others. The full list with the level and data source for each is above.

How many people does Cedar Creek Water serve?

Cedar Creek Water reports serving 3,720 people in Texas, per its EPA record.

Has Cedar Creek Water had any water quality violations?

The EPA has 5 violations on file for Cedar Creek Water, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.