← Texas

Tap water quality report

Forest Lake Subdivision

EPA monitoring tested this supplier for 78 contaminants and detected 24. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
24
detected
441
people served
8
health-based violations
Water source
SWP
Ownership
Private
Counties served
Gregg

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

8
health-based violations
17
violations on file
0
still open
ViolationTypeStatusPeriod
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Resolved 2013-09-01 → 2013-09-30
MCL Health-based Resolved 2013-08-01 → 2013-08-31
MCL Health-based Resolved 2013-08-01 → 2013-08-31
MCL Health-based Resolved 2013-08-01 → 2013-08-31
MCL Health-based Resolved 2013-08-01 → 2013-08-31
MR Monitoring Resolved 2021-12-30
MR Monitoring Resolved 2021-12-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Chloroform
39.625 µg/L
No EPA limit set
worst single sample: 59.9 µg/L
56/56 SYR4 2012–2019
TTHM
37.82 µg/L 47%
of the EPA limit 80 µg/L
worst single sample: 102.5 µg/L
44/44 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
19.53 µg/L 33%
of the EPA limit 60 µg/L
worst single sample: 45.6 µg/L
44/44 SYR4 2013–2019
Bromodichloromethane
22.3 µg/L
No EPA limit set
worst single sample: 40.9 µg/L
41/56 SYR4 2012–2019
Dichloroacetic Acid
14.9 µg/L
No EPA limit set
worst single sample: 25.2 µg/L
40/44 SYR4 2013–2019
Nitrate
190.9 µg/L 1.9%
of the EPA limit 10000 µg/L
worst single sample: 208 µg/L
30/30 SYR4 2012–2019
Dibromochloromethane
20.86 µg/L
No EPA limit set
worst single sample: 21.2 µg/L
18/56 SYR4 2012–2019
Trichloroacetic Acid
5.63 µg/L
No EPA limit set
worst single sample: 6.4 µg/L
15/44 SYR4 2013–2019
Copper
136.06 µg/L 10%
of the EPA limit 1300 µg/L
worst single sample: 208 µg/L
12/14 SYR4 2012–2018
Monochloroacetic Acid
9.1 µg/L
No EPA limit set
worst single sample: 15.1 µg/L
11/44 SYR4 2013–2019
Monobromoacetic Acid
5.625 µg/L
No EPA limit set
worst single sample: 6.3 µg/L
10/44 SYR4 2013–2019
Bromoform
8.752 µg/L
No EPA limit set
worst single sample: 9.58 µg/L
9/56 SYR4 2012–2019
Dibromoacetic Acid
3.15 µg/L
No EPA limit set
worst single sample: 3.6 µg/L
6/44 SYR4 2013–2019
Lead
0.0113 mg/L 75%
of the EPA limit 0.0150 mg/L
6/6 LCR 2025
Barium
236 µg/L 12%
of the EPA limit 2000 µg/L
worst single sample: 240 µg/L
5/5 SYR4 2012–2018
Fluoride
392.4 µg/L 9.8%
of the EPA limit 4000 µg/L
worst single sample: 393 µg/L
5/5 SYR4 2012–2018
Nitrate-Nitrite
96.6 µg/L 1%
of the EPA limit 10000 µg/L
worst single sample: 98 µg/L
5/5 SYR4 2012–2019
Cyanide
29.31 µg/L 15%
of the EPA limit 200 µg/L
worst single sample: 29.4 µg/L
4/5 SYR4 2012–2018
Lead
1.591 µg/L 11%
of the EPA limit 15 µg/L
worst single sample: 1.6 µg/L
4/14 SYR4 2012–2018
Chromium
1.198 µg/L 1.2%
of the EPA limit 100 µg/L
worst single sample: 1.2 µg/L
3/5 SYR4 2012–2018
Arsenic
1.26905 µg/L 13%
of the EPA limit 10 µg/L
worst single sample: 1.3 µg/L
2/5 SYR4 2012–2018
Thallium, Total
0.0320 µg/L 1.6%
of the EPA limit 2 µg/L
1/5 SYR4 2012–2018
Toluene
1.93 µg/L 0.2%
of the EPA limit 1000 µg/L
1/12 SYR4 2012–2019
Xylenes, Total
1.44 µg/L 0%
of the EPA limit 10000 µg/L
1/12 SYR4 2012–2019
54 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneToxapheneTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FOLTZ, SCOT, W
Phone
512-990-4400
Email
[email protected]

Frequently asked questions about Forest Lake Subdivision

Is Forest Lake Subdivision tap water safe to drink?

EPA monitoring detected 24 contaminants in Forest Lake Subdivision's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Forest Lake Subdivision's water?

EPA monitoring detected Chloroform, TTHM, Total Haloacetic Acids (HAA5), Bromodichloromethane, Dichloroacetic Acid, and others. The full list with the level and data source for each is above.

How many people does Forest Lake Subdivision serve?

Forest Lake Subdivision reports serving 441 people in Texas, per its EPA record.

Has Forest Lake Subdivision had any water quality violations?

The EPA has 17 violations on file for Forest Lake Subdivision, of which 8 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.