← Texas

Tap water quality report

C H Wsc

EPA monitoring tested this supplier for 78 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

78
contaminants tested
17
detected
261
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Freestone

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
15
violations on file
1
still open
ViolationTypeStatusPeriod
Other Monitoring Unaddressed 2025-07-01
MR Monitoring Resolved 2021-05-25
MR Monitoring Resolved 2021-05-25
MR Monitoring Resolved 2021-05-25
MR Monitoring Resolved 2021-05-25
MR Monitoring Resolved 2017-12-30
MR Monitoring Resolved 2017-12-30
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2014-12-30
MR Monitoring Resolved 2013-04-01 → 2013-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
50 µg/L 0.5%
of the EPA limit 10000 µg/L
16/16 SYR4 2012–2019
Bromodichloromethane
5.32 µg/L
No EPA limit set
worst single sample: 5.54 µg/L
11/11 SYR4 2012–2019
Bromoform
7.215 µg/L
No EPA limit set
worst single sample: 8.1 µg/L
11/11 SYR4 2012–2019
Dibromochloromethane
10.8 µg/L
No EPA limit set
worst single sample: 11 µg/L
11/11 SYR4 2012–2019
Chloroform
2.5435 µg/L
No EPA limit set
worst single sample: 2.89 µg/L
10/11 SYR4 2012–2019
Copper
85.8 µg/L 6.6%
of the EPA limit 1300 µg/L
worst single sample: 99 µg/L
9/11 SYR4 2014–2017
Dichloroacetic Acid
1.87 µg/L
No EPA limit set
worst single sample: 1.9 µg/L
3/3 SYR4 2012–2019
Fluoride
358.2 µg/L 9%
of the EPA limit 4000 µg/L
worst single sample: 360 µg/L
3/3 SYR4 2013–2019
Nitrate-Nitrite
48.75 µg/L 0.5%
of the EPA limit 10000 µg/L
worst single sample: 50 µg/L
3/3 SYR4 2012–2015
TTHM
26.2 µg/L 33%
of the EPA limit 80 µg/L
worst single sample: 26.3 µg/L
3/3 SYR4 2012–2019
Total Haloacetic Acids (HAA5)
5.36 µg/L 8.9%
of the EPA limit 60 µg/L
worst single sample: 5.4 µg/L
3/3 SYR4 2012–2019
Barium
29 µg/L 1.5%
of the EPA limit 2000 µg/L
2/2 SYR4 2016–2019
Chromium
2.675 µg/L 2.7%
of the EPA limit 100 µg/L
worst single sample: 2.7 µg/L
2/2 SYR4 2016–2019
Dibromoacetic Acid
3.495 µg/L
No EPA limit set
worst single sample: 3.5 µg/L
2/3 SYR4 2012–2019
Cyanide
5.74 µg/L 2.9%
of the EPA limit 200 µg/L
1/2 SYR4 2014–2017
Lead
0.0 mg/L 0%
of the EPA limit 0.0150 mg/L
1/1 LCR 2023
Lead
1.4 µg/L 9.3%
of the EPA limit 15 µg/L
1/11 SYR4 2014–2017
61 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane2,4,5-TP2,4-DAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCadmiumCarbofuranCarbon TetrachlorideChlordaneCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNitriteOxamylPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
MURDEN, GUY
Phone
254-739-3007

Frequently asked questions about C H Wsc

Is C H Wsc tap water safe to drink?

EPA monitoring detected 17 contaminants in C H Wsc's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in C H Wsc's water?

EPA monitoring detected Nitrate, Bromodichloromethane, Bromoform, Dibromochloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does C H Wsc serve?

C H Wsc reports serving 261 people in Texas, per its EPA record.

Has C H Wsc had any water quality violations?

The EPA has 15 violations on file for C H Wsc, of which 0 are health-based (a contaminant limit or required treatment was breached) and 1 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.