Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| MCL | Health-based | Archived | 1993-10-01 → 1993-10-31 |
| MCL | Health-based | Archived | 1993-07-01 → 1993-07-31 |
| MCL | Health-based | Archived | 1993-06-01 → 1993-06-30 |
| MCL | Health-based | Archived | 1991-01-01 → 1991-01-31 |
| MCL | Health-based | Archived | 1991-01-01 → 1991-01-31 |
| MR | Monitoring | Unaddressed | 2025-12-30 |
| RPT | Monitoring | Unaddressed | 2025-07-02 |
| Other | Monitoring | Resolved | 2025-07-01 |
| Other | Monitoring | Resolved | 2025-07-01 |
| Other | Monitoring | Resolved | 2023-07-01 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 128.6 µg/L 9.9% of the EPA limit 1300 µg/L
worst single sample: 768 µg/L | 25/32 | SYR4 | 2012–2018 |
| Bromoform | 35.36 µg/L No EPA limit set
worst single sample: 39.2 µg/L | 17/17 | SYR4 | 2014–2019 |
| Dibromochloromethane | 6.18 µg/L No EPA limit set
worst single sample: 6.9 µg/L | 17/17 | SYR4 | 2014–2019 |
| Dibromoacetic Acid | 6.685 µg/L No EPA limit set
worst single sample: 8.5 µg/L | 12/12 | SYR4 | 2014–2019 |
| Nitrate | 20 µg/L 0.2% of the EPA limit 10000 µg/L | 12/16 | SYR4 | 2012–2019 |
| TTHM | 44.055 µg/L 55% of the EPA limit 80 µg/L
worst single sample: 47.3 µg/L | 12/12 | SYR4 | 2014–2019 |
| Total Haloacetic Acids (HAA5) | 6.685 µg/L 11% of the EPA limit 60 µg/L
worst single sample: 8.5 µg/L | 12/12 | SYR4 | 2014–2019 |
| Lead | 12 µg/L 80% of the EPA limit 15 µg/L
worst single sample: 14 µg/L | 11/32 | SYR4 | 2012–2018 |
| Lead | 0.0093 mg/L 62% of the EPA limit 0.0150 mg/L | 10/10 | LCR | 2025 |
| Bromodichloromethane | 1.175 µg/L No EPA limit set
worst single sample: 1.2 µg/L | 6/17 | SYR4 | 2014–2019 |
| Arsenic | 4.48 µg/L 45% of the EPA limit 10 µg/L
worst single sample: 4.7 µg/L | 3/3 | SYR4 | 2012–2018 |
| Barium | 608.7 µg/L 30% of the EPA limit 2000 µg/L
worst single sample: 609 µg/L | 3/3 | SYR4 | 2012–2018 |
| Fluoride | 558 µg/L 14% of the EPA limit 4000 µg/L
worst single sample: 560 µg/L | 3/3 | SYR4 | 2012–2018 |
| Nitrate-Nitrite | 19.5 µg/L 0.2% of the EPA limit 10000 µg/L
worst single sample: 20 µg/L | 2/2 | SYR4 | 2013–2014 |
| Selenium | 14.455 µg/L 29% of the EPA limit 50 µg/L
worst single sample: 15 µg/L | 2/3 | SYR4 | 2012–2018 |
| Combined Radium (-226 And -228) | 2.2 pCi/L 44% of the EPA limit 5 pCi/L | 1/2 | SYR4 | 2012–2018 |
| Gross Alpha, Excl. Radon And U | 5.5 pCi/L 37% of the EPA limit 15 pCi/L | 1/1 | SYR4 | 2018 |
62 contaminants tested, none detected
Utility contact
Frequently asked questions about Town of Holiday Lakes
Is Town of Holiday Lakes tap water safe to drink?
EPA monitoring detected 17 contaminants in Town of Holiday Lakes's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Town of Holiday Lakes's water?
EPA monitoring detected Copper, Bromoform, Dibromochloromethane, Dibromoacetic Acid, Nitrate, and others. The full list with the level and data source for each is above.
How many people does Town of Holiday Lakes serve?
Town of Holiday Lakes reports serving 921 people in Texas, per its EPA record.
Has Town of Holiday Lakes had any water quality violations?
The EPA has 40 violations on file for Town of Holiday Lakes, of which 5 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.