Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2023-01-28 |
| TT | Health-based | Resolved | 2023-01-28 |
| TT | Health-based | Resolved | 2023-01-28 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-10-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-10-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-10-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-10-31 |
| MCL | Health-based | Resolved | 2006-10-01 → 2006-10-31 |
| MCL | Health-based | Resolved | 2006-04-01 → 2006-04-30 |
| MCL | Health-based | Resolved | 2006-04-01 → 2006-04-30 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 213 µg/L 16% of the EPA limit 1300 µg/L
worst single sample: 21000 µg/L | 381/383 | SYR4 | 2012–2019 |
| Lead | 59.5 µg/L 397% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 1300 µg/L | 190/382 | SYR4 | 2012–2019 |
| Chlorite | 939 µg/L 94% of the EPA limit 1000 µg/L
worst single sample: 1220 µg/L | 135/135 | SYR4 | 2016–2019 |
| Dibromochloromethane | 3.52 µg/L No EPA limit set
worst single sample: 4.1 µg/L | 45/119 | SYR4 | 2012–2019 |
| TTHM | 8.96 µg/L 11% of the EPA limit 80 µg/L
worst single sample: 18.5 µg/L | 45/103 | SYR4 | 2012–2019 |
| Nitrate | 2159 µg/L 22% of the EPA limit 10000 µg/L
worst single sample: 2210 µg/L | 38/38 | SYR4 | 2012–2019 |
| Bromoform | 3.15 µg/L No EPA limit set
worst single sample: 3.6 µg/L | 31/119 | SYR4 | 2012–2019 |
| Lead | 0.0010 mg/L 6.7% of the EPA limit 0.0150 mg/L | 16/16 | LCR | 2025 |
| Total Haloacetic Acids (HAA5) | 2.025 µg/L 3.4% of the EPA limit 60 µg/L
worst single sample: 2.1 µg/L | 16/104 | SYR4 | 2012–2019 |
| Bromodichloromethane | 3.69 µg/L No EPA limit set
worst single sample: 5.9 µg/L | 14/119 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 1.675 µg/L No EPA limit set
worst single sample: 2 µg/L | 14/104 | SYR4 | 2012–2019 |
| Barium | 108.34 µg/L 5.4% of the EPA limit 2000 µg/L
worst single sample: 115 µg/L | 5/5 | SYR4 | 2014–2019 |
| Fluoride | 1356 µg/L 34% of the EPA limit 4000 µg/L
worst single sample: 1630 µg/L | 5/5 | SYR4 | 2014–2019 |
| Nitrate-Nitrite | 2203 µg/L 22% of the EPA limit 10000 µg/L
worst single sample: 2210 µg/L | 3/3 | SYR4 | 2012–2015 |
| Chloroform | 7.41 µg/L No EPA limit set
worst single sample: 7.7 µg/L | 2/119 | SYR4 | 2012–2019 |
| Monochloroacetic Acid | 2.095 µg/L No EPA limit set
worst single sample: 2.1 µg/L | 2/104 | SYR4 | 2012–2019 |
| Arsenic | 2.1 µg/L 21% of the EPA limit 10 µg/L | 1/5 | SYR4 | 2014–2019 |
| Gross Alpha, Excl. Radon And U | 3.5 pCi/L 23% of the EPA limit 15 pCi/L | 1/4 | SYR4 | 2016–2019 |
| Selenium | 4.3 µg/L 8.6% of the EPA limit 50 µg/L | 1/5 | SYR4 | 2014–2019 |
| Lithium | 9.5 µg/L No EPA limit set | 1/6 | UCMR-5 | 2023 |
89 contaminants tested, none detected
Utility contact
Frequently asked questions about Jbsa Sam Houston
Is Jbsa Sam Houston tap water safe to drink?
EPA monitoring detected 20 contaminants in Jbsa Sam Houston's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Jbsa Sam Houston's water?
EPA monitoring detected Copper, Lead, Chlorite, Dibromochloromethane, TTHM, and others. The full list with the level and data source for each is above.
How many people does Jbsa Sam Houston serve?
Jbsa Sam Houston reports serving 37,563 people in Texas, per its EPA record.
Has Jbsa Sam Houston had any water quality violations?
The EPA has 206 violations on file for Jbsa Sam Houston, of which 19 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.