← Texas

Tap water quality report

Bexar County Wcid 10 Windcrest

EPA monitoring tested this supplier for 109 contaminants and detected 17. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
17
detected
8,154
people served
0
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Bexar

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

0
health-based violations
10
violations on file
0
still open
ViolationTypeStatusPeriod
Other Monitoring Resolved 2023-07-01
Other Monitoring Resolved 2023-07-01
MR Monitoring Resolved 2015-12-30
MR Monitoring Resolved 2015-12-30
MR Monitoring Resolved 2014-06-01 → 2014-06-30
MR Monitoring Resolved 2014-06-01 → 2014-06-30
MR Monitoring Resolved 2014-06-01 → 2014-06-30
MR Monitoring Resolved 2014-06-01 → 2014-06-30
MR Monitoring Resolved 2013-12-30
MR Monitoring Resolved 1992-07-01 → 1993-06-30

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Nitrate
2212.5 µg/L 22%
of the EPA limit 10000 µg/L
worst single sample: 2280 µg/L
66/70 SYR4 2012–2019
Copper
143.5 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 175 µg/L
64/64 SYR4 2013–2019
Lead
4.66 µg/L 31%
of the EPA limit 15 µg/L
worst single sample: 10.4 µg/L
39/64 SYR4 2013–2019
Nitrate-Nitrite
2226 µg/L 22%
of the EPA limit 10000 µg/L
worst single sample: 2280 µg/L
19/19 SYR4 2012–2019
Bromoform
4.26 µg/L
No EPA limit set
worst single sample: 4.9 µg/L
17/30 SYR4 2013–2019
Dibromochloromethane
5.52 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
17/30 SYR4 2013–2019
Lead
0.0014 mg/L 9.3%
of the EPA limit 0.0150 mg/L
14/14 LCR 2025
TTHM
3.865 µg/L 4.8%
of the EPA limit 80 µg/L
worst single sample: 4 µg/L
10/10 SYR4 2013–2019
Barium
94.925 µg/L 4.7%
of the EPA limit 2000 µg/L
worst single sample: 96.5 µg/L
8/8 SYR4 2016–2019
Fluoride
286.5 µg/L 7.2%
of the EPA limit 4000 µg/L
worst single sample: 290 µg/L
8/8 SYR4 2014–2017
Bromodichloromethane
4.65 µg/L
No EPA limit set
worst single sample: 5.3 µg/L
6/30 SYR4 2013–2019
Combined Radium (-226 And -228)
2.86 pCi/L 57%
of the EPA limit 5 pCi/L
worst single sample: 3.1 pCi/L
4/4 SYR4 2013–2016
Chloroform
3.93 µg/L
No EPA limit set
worst single sample: 4.2 µg/L
3/30 SYR4 2013–2019
Dibromoacetic Acid
1.095 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
2/10 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
1.095 µg/L 1.8%
of the EPA limit 60 µg/L
worst single sample: 1.1 µg/L
2/10 SYR4 2013–2019
Gross Alpha, Excl. Radon And U
3.1 pCi/L 21%
of the EPA limit 15 pCi/L
1/6 SYR4 2013–2019
Xylenes, Total
1.7 µg/L 0%
of the EPA limit 10000 µg/L
1/20 SYR4 2015–2019
92 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDichloroacetic AcidDinosebEthylene DibromideEndrinEthylbenzeneGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroacetic AcidTrichloroethyleneVinyl Chloridecis-1,2-DichloroethyleneLithiumO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
ALEXANDER, SUE
Phone
210-655-2888

Frequently asked questions about Bexar County Wcid 10 Windcrest

Is Bexar County Wcid 10 Windcrest tap water safe to drink?

EPA monitoring detected 17 contaminants in Bexar County Wcid 10 Windcrest's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in Bexar County Wcid 10 Windcrest's water?

EPA monitoring detected Nitrate, Copper, Lead, Nitrate-Nitrite, Bromoform, and others. The full list with the level and data source for each is above.

How many people does Bexar County Wcid 10 Windcrest serve?

Bexar County Wcid 10 Windcrest reports serving 8,154 people in Texas, per its EPA record.

Has Bexar County Wcid 10 Windcrest had any water quality violations?

The EPA has 10 violations on file for Bexar County Wcid 10 Windcrest, of which 0 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.