Compliance record
Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.
| Violation | Type | Status | Period |
|---|---|---|---|
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Resolved | 2024-10-17 |
| TT | Health-based | Unaddressed | 2023-06-15 |
| TT | Health-based | Unaddressed | 2023-06-15 |
| TT | Health-based | Unaddressed | 2023-06-15 |
| TT | Health-based | Resolved | 2017-03-31 |
| TT | Health-based | Resolved | 2017-03-31 |
| TT | Health-based | Resolved | 2017-03-31 |
Other contaminants detected
| Contaminant | Level vs EPA limit | Detection rate | Source | Period |
|---|---|---|---|---|
| Copper | 1200 µg/L 92% of the EPA limit 1300 µg/L
worst single sample: 1900 µg/L | 94/100 | SYR4 | 2012–2019 |
| Lead | 18.93 µg/L 126% of the EPA limit, at the 95th percentile of samples — 15 µg/L
worst single sample: 35 µg/L | 68/100 | SYR4 | 2012–2019 |
| Bromodichloromethane | 18.365 µg/L No EPA limit set
worst single sample: 18.9 µg/L | 62/62 | SYR4 | 2012–2019 |
| Chloroform | 21.31 µg/L No EPA limit set
worst single sample: 32 µg/L | 62/62 | SYR4 | 2012–2019 |
| Dibromochloromethane | 11.175 µg/L No EPA limit set
worst single sample: 14.8 µg/L | 62/62 | SYR4 | 2012–2019 |
| Dichloroacetic Acid | 20.29 µg/L No EPA limit set
worst single sample: 23.7 µg/L | 62/62 | SYR4 | 2012–2019 |
| TTHM | 48.5 µg/L 61% of the EPA limit 80 µg/L
worst single sample: 55 µg/L | 62/62 | SYR4 | 2012–2019 |
| Total Haloacetic Acids (HAA5) | 32.455 µg/L 54% of the EPA limit 60 µg/L
worst single sample: 40.9 µg/L | 62/62 | SYR4 | 2012–2019 |
| Dibromoacetic Acid | 5.61 µg/L No EPA limit set
worst single sample: 6.9 µg/L | 59/62 | SYR4 | 2012–2019 |
| Trichloroacetic Acid | 7.34 µg/L No EPA limit set
worst single sample: 14.3 µg/L | 59/62 | SYR4 | 2012–2019 |
| Bromoform | 3.86 µg/L No EPA limit set
worst single sample: 4.4 µg/L | 38/62 | SYR4 | 2012–2019 |
| Lead | 0.0 mg/L 0% of the EPA limit 0.0150 mg/L | 21/21 | LCR | 2026 |
| Monochloroacetic Acid | 3.66 µg/L No EPA limit set
worst single sample: 3.7 µg/L | 5/62 | SYR4 | 2012–2019 |
1 contaminants tested, none detected
Utility contact
Frequently asked questions about Central Texas College Killeen
Is Central Texas College Killeen tap water safe to drink?
EPA monitoring detected 13 contaminants in Central Texas College Killeen's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.
What contaminants were detected in Central Texas College Killeen's water?
EPA monitoring detected Copper, Lead, Bromodichloromethane, Chloroform, Dibromochloromethane, and others. The full list with the level and data source for each is above.
How many people does Central Texas College Killeen serve?
Central Texas College Killeen reports serving 2,330 people in Texas, per its EPA record.
Has Central Texas College Killeen had any water quality violations?
The EPA has 69 violations on file for Central Texas College Killeen, of which 15 are health-based (a contaminant limit or required treatment was breached) and 3 remain open. The rest are monitoring or reporting failures.
Where does this data come from?
Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.