← Texas

Tap water quality report

City of Smithville

EPA monitoring tested this supplier for 109 contaminants and detected 18. A detection doesn't automatically mean the water is unsafe — the level and EPA source for each is below.

109
contaminants tested
18
detected
4,901
people served
5
health-based violations
Water source
Ground water
Ownership
Local government
Counties served
Bastrop

Compliance record

Formal violations the EPA has on file for this supplier. A health-based violation means a contaminant limit or a required treatment was breached; the rest are monitoring or reporting failures — still violations, but not a measured health risk.

5
health-based violations
119
violations on file
0
still open
ViolationTypeStatusPeriod
TT Health-based Resolved 2017-11-13
TT Health-based Resolved 2017-11-13
TT Health-based Resolved 2017-11-13
TT Health-based Resolved 2017-11-13
MCL Health-based Archived 1991-10-01 → 1991-10-31
MR Monitoring Resolved 2024-12-30
MR Monitoring Resolved 2024-12-30
MR Monitoring Resolved 2020-10-01
MR Monitoring Resolved 2020-10-01
MR Monitoring Resolved 2020-10-01

Other contaminants detected

Each bar shows the measured level as a share of the EPA limit: green is well under, amber is close to it, red is over. For lead and copper the limit applies to exactly the 90th-percentile figure shown, so red there means a real exceedance. For everything else the limit applies to a running annual average while the figure is the 95th percentile of this system's samples — over 100% is worth reading, but is not by itself a violation. Where a single sample came in higher than that percentile, it is noted under the bar. Formal violations are listed separately.
ContaminantLevel vs EPA limitDetection rateSourcePeriod
Copper
142.5 µg/L 11%
of the EPA limit 1300 µg/L
worst single sample: 340 µg/L
36/42 SYR4 2014–2017
Nitrate
160 µg/L 1.6%
of the EPA limit 10000 µg/L
16/18 SYR4 2012–2019
Lead
0.00098 mg/L 6.5%
of the EPA limit 0.0150 mg/L
15/15 LCR 2024
Bromodichloromethane
6.8865 µg/L
No EPA limit set
worst single sample: 7.2 µg/L
12/13 SYR4 2013–2019
Chloroform
5.1105 µg/L
No EPA limit set
worst single sample: 5.6 µg/L
12/13 SYR4 2013–2019
Dibromochloromethane
6.6165 µg/L
No EPA limit set
worst single sample: 7.37 µg/L
12/13 SYR4 2013–2019
Dichloroacetic Acid
3.37 µg/L
No EPA limit set
worst single sample: 3.4 µg/L
7/7 SYR4 2013–2019
TTHM
21.52 µg/L 27%
of the EPA limit 80 µg/L
worst single sample: 22 µg/L
7/7 SYR4 2013–2019
Total Haloacetic Acids (HAA5)
6.26 µg/L 10%
of the EPA limit 60 µg/L
worst single sample: 6.5 µg/L
7/7 SYR4 2013–2019
Lead
3.3 µg/L 22%
of the EPA limit 15 µg/L
worst single sample: 3.5 µg/L
6/42 SYR4 2014–2017
Barium
47.62 µg/L 2.4%
of the EPA limit 2000 µg/L
worst single sample: 51.4 µg/L
4/4 SYR4 2016–2019
Nitrate-Nitrite
136.7 µg/L 1.4%
of the EPA limit 10000 µg/L
worst single sample: 140 µg/L
4/4 SYR4 2012–2019
Trichloroacetic Acid
2.34 µg/L
No EPA limit set
worst single sample: 2.4 µg/L
4/7 SYR4 2013–2019
Lithium
43 µg/L
No EPA limit set
4/4 UCMR-5 2025
Bromoform
3.166 µg/L
No EPA limit set
worst single sample: 3.34 µg/L
3/13 SYR4 2013–2019
Fluoride
110 µg/L 2.8%
of the EPA limit 4000 µg/L
3/3 SYR4 2014–2019
Dibromoacetic Acid
1.095 µg/L
No EPA limit set
worst single sample: 1.1 µg/L
2/7 SYR4 2013–2019
Combined Radium (-226 And -228)
2.6 pCi/L 52%
of the EPA limit 5 pCi/L
1/1 SYR4 2015
91 contaminants tested, none detected
1,1,1-Trichloroethane1,1,2-Trichloroethane1,1-Dichloroethylene1,2,4-Trichlorobenzene1,2-DIBROMO-3-CHLOROPROPANE1,2-Dichloroethane1,2-Dichloropropane11Cl-PF3OUdS2,4,5-TP2,4-D4:2 Fts6:2 Fts8:2 Fts9Cl-PF3ONSAdonaAntimony, TotalArsenicAsbestosAtrazineBhc-GammaBenzeneBenzo(A)PyreneBeryllium, TotalChlorobenzeneCyanideCadmiumCarbofuranCarbon TetrachlorideChlordaneChromiumCombined UraniumDichloromethaneDalaponDi(2-ethylhexyl) AdipateDi(2-ethylhexyl) PhthalateDinosebEthylene DibromideEndrinEthylbenzeneGross Alpha, Excl. Radon And UGross Beta Particle ActivityHexachlorobenzeneHfpo-DaHeptachlorHeptachlor EpoxideHexachlorocyclopentadieneLassoMercuryMethoxychlorMonobromoacetic AcidMonochloroacetic AcidNetfosaaNfdhaNmefosaaNitriteOxamylPfbaPFBSPfdaPfdoaPfeesaPfhpaPfhpsPfhxaPFHXSPfmbaPfmpaPFNAPFOAPFOSPfpeaPfpesPftaPftrdaPfunaPentachlorophenolPicloramSeleniumSimazineStyreneTetrachloroethyleneThallium, TotalTolueneToxapheneTrichloroethyleneVinyl ChlorideXylenes, Totalcis-1,2-DichloroethyleneO-DichlorobenzeneP-Dichlorobenzenetrans-1,2-Dichloroethylene

Utility contact

Contact
FOERSTER, SHARON
Phone
512-237-3282
Email
[email protected]

Frequently asked questions about City of Smithville

Is City of Smithville tap water safe to drink?

EPA monitoring detected 18 contaminants in City of Smithville's water. A detection isn't the same as a violation — most levels are within federal limits. See each level and source above, and the utility's annual Consumer Confidence Report for its official compliance status.

What contaminants were detected in City of Smithville's water?

EPA monitoring detected Copper, Nitrate, Lead, Bromodichloromethane, Chloroform, and others. The full list with the level and data source for each is above.

How many people does City of Smithville serve?

City of Smithville reports serving 4,901 people in Texas, per its EPA record.

Has City of Smithville had any water quality violations?

The EPA has 119 violations on file for City of Smithville, of which 5 are health-based (a contaminant limit or required treatment was breached) and 0 remain open. The rest are monitoring or reporting failures.

Where does this data come from?

Every figure is official EPA drinking-water monitoring — the Lead & Copper Rule, the UCMR-5 nationwide testing program, and the EPA Six-Year Review — not our own testing. Each number is labelled with its source and period.